GENERAL
The 40VMU under ceiling/floor unit can be installed ex-
posed at the ceiling or mounted on the wall close to the floor. It
is ideal for corner or low-ceiling areas where soffit space is not
available for furred-in units.
The equipment is initially protected under the manufactur-
er’s standard warranty; however, the warranty is provided un-
der the condition that the steps outlined in this manual for ini-
tial inspection, proper installation, regular periodic mainte-
nance, and everyday operation of the unit be followed in detail.
This manual should be fully reviewed in advance before initial
installation, start-up and any maintenance. Contact your local
sales representative or the factory with any questions BEFORE
proceeding.
Table 1 lists physical data for each unit size. See Fig. 1 for
the model number nomenclature. Figures 2 and 3 show the unit
dimensions. Table 2 shows components that may or may not be
used for a particular installation.
Table 1 — 40VMU Physical Data
LEGEND
CAUTION
DO NOT re-use compressor oil or any oil that has been
exposed to the atmosphere. Dispose of oil per local codes
and regulations. DO NOT leave refrigerant system open to
air any longer than the actual time required to service the
equipment. Seal circuits being serviced and charge with
dry nitrogen to prevent oil contamination when timely
repairs cannot be completed. Failure to follow these proce-
dures may result in damage to equipment. For information
about replacement oil type and viscosity, see the Installa-
tion, Start-Up, and Service Instructions for the 38VMAH
and 38VMAR outdoor units.
UNIT 40VMU
012
015
018
024
030
036
048
POWER SUPPLY (V-Ph-Hz)
208/230-1-60
COOLING CAPACITY (Btuh)
12,000
15,000
18,000
24,000
30,000
36,000
48,000
HEATING CAPACITY (Btuh)
13,500
17,000
21,000
27,000
34,000
40,000
54,000
INDOOR FAN MOTOR
Type
DC Motor
Input (W)
24
47
53
80
107
67*2
115*2
INDOOR COIL
Number of Rows
2
3
Fin Spacing (fins/in.)
15
14
Fin Type
Aluminum with Hydrophilic Coating
Tube Diameter, OD (in.)
3
/
8
Tube Type
Copper Tube with Inner Groove
Number of Circuits
3
5
7
INDOOR AIRFLOW (cfm)
Low
259
359
394
494
624
906
929
Medium
294
412
424
529
676
976
1000
High
335
441
471
571
729
1094
1353
INDOOR NOISE LEVEL (dBA)
Low
35.8
41.7
44.1
50.2
50.4
48.4
50.6
Medium
37.7
45.4
46.5
52.0
52.1
50.3
52.3
High
40.5
47.2
48.5
53.8
53.9
53.0
59.8
UNIT
Unit Dimensions, W x H x D (in.)
39 x 26 x 8
50
1
/
2
x 26
x 8
66 x 27 x 10
Packing Dimensions, W x H x D (in.)
43 x 29
1
/
2
x 12
55 x 29
1
/
2
x 12
75
1
/
2
x 30 x 13
Net/Gross Weight (lb)
57/71
62/75
77/90
106/128
REFRIGERANT TYPE
R-410A
EXPANSION DEVICE
EEV (Built-In)
DESIGN PRESSURE, High/Low (psig)
580/320
REFRIGERANT PIPING (in.)
Liquid Side, OD
1
/
4
3
/
8
Suction Side, OD
1
/
2
5
/
8
CONNECTING WIRING (AWG)
Power Wiring
Sized per NEC and Local Codes Based on Nameplate Electrical Data
Signal Wiring
2-Core Stranded Shielded Twisted Pair Cable 20 AWG-16 AWG
DRAINAGE WATER PIPE DIAMETER, OD (in.)
5
/
8
AWG
—
American Wire Gage
EEV
—
Electronic Expansion Valve
NEC
—
National Electrical Code
Содержание 40VMU012 Series
Страница 19: ......