A NOTE ABOUT SAFETY

Any time you see this symbol 

 in manuals, instructions and on the unit, 

be aware of the potential for personal injury. 

There are 3 levels of 

precaution

:

1.

DANGER

 identifies the most serious hazards which will result in 

severe personal injury or death. 

2.

WARNING

 signifies hazards that could result in personal injury 

or death. 

3.

CAUTION

 is used to identify unsafe practices which could 

result in minor personal injury or product and property damage.

NOTE

 is used to highlight suggestions which will result in enhanced 

installation, reliability, or operation.

GENERAL

The high wall fan coil unit provides quiet, maximum comfort. In 
addition to cooling and/or heating, the high wall fan coil unit matched 
with an outdoor condensing unit filters and dehumidifies the air in the 
room to provide maximum comfort.

IMPORTANT:

 The high wall fan coil unit should be installed by 

authorized personnel only; using approved tubing and accessories. If 
technical assistance, service or repair is needed, contact the installer. 
The high wall fan coil unit can be set up and operated from the remote 
control (provided). 

If the remote is misplaced, the system can be 

operated from the “Auto” setting on the unit.

Operating Modes

The high wall fan coil unit has five operating modes:

• FAN Only
• AUTO
• HEATING (heat pumps only)
• COOLING
• DEHUMIDIFICATION

FAN Only

In the 

FAN Only

 mode, the system filters and circulates the room air 

without changing room air temperature.

AUTO 

In the 

AUTO

 mode, the system automatically cools or heats the room 

according to the user-selected set point. 

NOTE: AUTO mode is recommended for use on single zone 

applications ONLY. Using AUTO CHANGEOVER on 
multi-zone applications could set an indoor unit to 
STANDBY mode, indicated with two dashes (--) on the 
display, which will turn off the indoor unit until all the 
indoor units are in the same mode (COOLING or 
HEATING). HEATING is the system's priority mode. 
Simultaneous HEATING and COOLING is not allowed.

HEATING

In the 

HEATING

 mode, the system heats and filters the room air.

COOLING

In the 

COOLING

 mode, the system cools, dries and filters the room 

air.

DEHUMIDIFICATION (DRY)

In the 

DEHUMIDIFICATION

 mode, the system dries, filters and 

slightly cools the room air temperature. This mode prioritizes air 
dehumidification but it does not take the place of a dehumidifier. This 
feature cannot be used in a multi-zone system.

Wireless Remote Control

The remote control transmits commands to set up and operate the 
system. The control has a window display panel that displays the 
current system status. The control can be secured to a surface when 
used with the mounting bracket provided.

Wired Remote Control (Optional)

Refer to the Wired Controller manual.

24V Interface (Optional)

Allows the control of the Ductless System with a third party thermostat.

Smartphone Control (Optional)

Capability to be controlled by a smartphone adding the Wi-Fi® 
Interface Kit 

KSAIF0601AAA.

PERSONAL INJURY, DEATH AND / OR PROPERTY 
DAMAGE HAZARD

Failure to follow this warning could result in personal injury, death or 
property damage.

Improper installation, adjustment, alteration, service, maintenance, or 
use can cause explosion, fire, electrical shock, or other conditions 
which may cause personal injury or property damage. Consult a 
qualified installer, service agency, or your distributor or branch for 
information or assistance. The qualified installer or service agency 
must use factory-authorized kits or accessories when modifying this 
product.

Read and follow all instructions and warnings, including labels 
shipped with or attached to unit before operating your new air 
conditioner.

WARNING

Содержание 40MPHB

Страница 1: ...model and serial numbers of your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maint...

Страница 2: ...Y Using AUTO CHANGEOVER on multi zone applications could set an indoor unit to STANDBY mode indicated with two dashes on the display which will turn off the indoor unit until all the indoor units are...

Страница 3: ...40MPHB Owner s Manual Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations 3 PART NAMES AND DISPLAY A220199 Fig 1 Indoor Unit...

Страница 4: ...ESH feature is not available RG10P1 2HS BGEF RG10P1 2HS BGEFU1 Model 18K RG10L 2HS BGEF and RG10L 2HS BGEFU1 FRESH feature is not available RG10L1 2HS BGEF RG10L1 2HS BGEFU1 RG10L10 2HS BGEF 20 28 C 6...

Страница 5: ...serves the right to change at any time specifications and designs without notice and without obligations 5 WIRELESS REMOTE CONTROL LCD SCREEN INDICATORS A220202 Fig 3 Wireless Remote Controller Indica...

Страница 6: ...battery compartment cover NOTES 1 When replacing batteries do not use old batteries or a different type battery This may cause the remote control to malfunction 2 If the remote is not going to be use...

Страница 7: ...ir conditioner in conjunction with other heating appliances AUTO Mode In AUTO mode the unit automatically selects the COOL FAN or HEAT operation based on the set temperature A220208 Fig 6 AUTO Mode 1...

Страница 8: ...grease that may cause odors when it adheres to the heat exchanger by automatically freezing and then rapidly thawing the frost When this function is turned on the indoor unit window displays CL after...

Страница 9: ...leakage Occupancy Sensor The system is controlled intelligently under the Occupancy Sensor mode The feature detects the movement in the room In COOLING mode when occupants are away for 30 minutes the...

Страница 10: ...with Electric heat elements the electric heater activates and jump starts the heating process Manual Operation without remote control The manual button is intended for testing purposes and emergency o...

Страница 11: ...ing filter un clip it from the larger filter Clean the air freshening filter with a hand held vacuum 5 Clean the large air filter with warm soapy water Be sure to use a mild detergent 6 Rinse the filt...

Страница 12: ...5 Rinse the filter with fresh water then shake off any excess water 6 Dry the filter in a cool dry place and refrain from exposing it to direct sunlight 7 When dry re clip the air freshening filter t...

Страница 13: ...resolved Do not perform cleaning or maintenance activities while the unit is on Keep the display panel on the unit away from direct sunlight and heat as this may interfere with remote control transmis...

Страница 14: ...nits emit white mist When the unit restarts in HEAT mode after defrosting white mist may be emitted due to moisture generated from the defrosting process The indoor unit makes noises A rushing air sou...

Страница 15: ...r service representative Cooling is Not Working Properly The filter is blocked by dust Temperature is not set properly A window or door is open The outdoor unit is obstructed The fan speed is too low...