Troubleshooting

Refer to Table 2 before contacting your local dealer.

Table 1—Periodic Maintenance

INDOOR UNIT

EVERY MONTH

EVERY 6 MONTHS

EVERY YEAR

Clean Air Filter*

Change Remote Control Batteries

S

S

S

OUTDOOR UNIT

EVERY MONTH

EVERY 6 MONTHS

EVERY YEAR

Clean Outdoor Coil from Outside

Clean Outdoor Coil from Inside†

Blow Air Over Electric Parts†

Check Electric Connection Tightening†

Clean Fan Wheel†

Check Fan Tightening†

Clean Drain Pans†

S

S
S
S
S
S
S

* Increase frequency in dusty zones.

{

Maintenance to be carried out by qualified service personnel. Refer to the Installation Manual

Table 2—Troubleshooting

PROBLEM

POSSIBLE CAUSE

SOLUTION

Unit/System Does Not Work

The circuit breaker has tripped or a fuse

has blown.

Power failure.

Diagnostic lights illuminate.

*

Voltage is too low.

Reset the circuit breaker or replace the fuse with

the specified replacement fuse.

Restart operation when the power is restored.

Call your service representative.

Call your service representative.

Cooling is Not Working

Properly

The filter is blocked with dust.

Temperature is not set properly.

A window or door is open.

The outdoor unit is obstructed.

The fan speed is too low.

The operation mode is in Fan instead of

Cool.

Clean the air filter.

Check the temperature and reset if necessary.

Close the window or door.

Remove the obstruction.

Change the fan speed selection.

Change the operating mode to Cool or reset the

unit.

Heating is Not Working

Properly

The filter is blocked with dust.

Temperature is set too low.

A window or door is open.

The outdoor unit is obstructed.

Clean the air filter.

Check the temperature and reset if necessary.

Close the window or door.

Remove the obstruction.

Unit Stops During Operation

The Off timer is not operating correctly.

Diagnostic lights illuminate.

*

Restart the operating mode.

Call your service representative.

* Diagnostic lights are a combination of lights that will illuminate in the display area on the unit. They are a combination of the lights you see during normal

operation.

Downloaded from 

ManualsNet.com

 search engine

Содержание 40MK B Series

Страница 1: ... spaces provided This information along with the installation data and dealer contact information will be helpful should your system require maintenance or service UNIT INFORMATION Model ___________________________________ Serial ___________________________________ INSTALLATION INFORMATION Date Installed _____________________________ DEALERSHIP CONTACT INFORMATION Company Name ____________________...

Страница 2: ... to cooling and or heating the high wall fan coil unit matched with an outdoor condensing unit will filter and dehumidify the air in the room to provide maximum comfort IMPORTANT The high wall fan coil unit should be installed by authorized personnel only using approved tubing and accessories If technical assistance service or repair is needed contact the installer The high wall fan coil unit can ...

Страница 3: ...t 12 Self tapping screws A14354 Fig 1 Indoor Outdoor Unit 1 2 4 5 6 7 8 9 10 11 3 Self Clean Follow Me LED Turbo Ionizer Smart Eye F P Silence Mode On Off Fan SLEEP Swing Timer TEMP AUTO COOL DRY HEAT FAN HIGH MED LOW 1 Temp Up Temp Down Buttons 2 Mode Button 3 On Off Button 4 Horizontal Swing Vertical Swing Buttons 5 Self Clean Button 6 Follow Me Button 7 Fan Button 8 Timer On Timer Off Buttons 9...

Страница 4: ...emote control transmits signals to the indoor unit 3 TEMPERATURE TIMER DISPLAY Temperature setting from 62_F 17_C to 86_F 30_C or set times for the timer operation 0 24h will be displayed If FAN mode is selected there will be no temperature displayed 4 ON OFF INDICATOR This symbol appears when the unit is turned on by the remote control and disappears when the unit is turned off 5 FAN MODE DISPLAY...

Страница 5: ...oing to be used for several weeks remove the batteries Otherwise battery leakage may damage the remote control 3 The average battery life under normal use is about 6 months 4 Replace the batteries when there is no audible beep from the indoor unit or if the Transmission Indicator fails to light 5 When batteries are removed the remote control erases all programmed settings The control must be repro...

Страница 6: ...ep and the value of the set temperature on the display will change accordingly The temperature can be set between 62_F 17_C and 86_F 30_C in increments of 1_F or 1_C NOTE In Cooling mode if the temperate selected is higher than the room temperature the unit will not start The same applies for the Heating mode if the selected temperature is lower than the room temperature Selecting the Fan Speed AU...

Страница 7: ...usly described Set TIME ON as previously described The unit will turn off automatically at the set TIME OFF and will turn on at the set TIME ON Sleep Mode This mode is used to conserve energy and can be used when the unit is in the COOL HEAT or AUTO mode only Cool Mode Push the SLEEP button After 1 hour the set point will be raised by 1 8_F 1_C After another hour the set point will be raised by an...

Страница 8: ...rush to avoid damage to the coil fins Air Filters Remove and clean the air filters once a month NOTE If air filters show signs of excessive wear or are torn they must be replaced Contact your local dealer for replacement filters 1 Open front panel on unit 2 Pull filters down to remove 3 Vacuum filters 4 Clean with warm water 5 Shake filter to remove excess water and dry thoroughly 6 Replace filter...

Страница 9: ...your service representative Call your service representative Cooling is Not Working Properly The filter is blocked with dust Temperature is not set properly A window or door is open The outdoor unit is obstructed The fan speed is too low The operation mode is in Fan instead of Cool Clean the air filter Check the temperature and reset if necessary Close the window or door Remove the obstruction Cha...

Страница 10: ... Indianapolis IN 46231 Edition Date 05 15 Manufacturer reserves the right to change at any time specifications and designs without notice and without obligations Catalog No OM40MKC Q B B 01 Replaces NEW Downloaded from ManualsNet com search engine ...

Отзывы: