LED Display
FP Function
LOCK Function
LED DISPLAY
2s
Keep pressing
LED
more than 5 seconds, the
indoor unit displays the actual room temperature.
Press more than 5 seconds again to revert back
which displays the setting temperature.
Press
LED
to turn on and turn off
the display on the indoor unit.
5s
Press LED
Press
LED
more
than 5 seconds (some units)
Keep pressing
Fan
for more than 2 seconds to activate/disable the
Silence
function (some units).
Due to the low frequency operation of the compressor, it may result in insufficient
cooling and heating capacity. Press
ON/OFF
,
Mode
,
Sleep
,
Turbo
or
Clean
while operating to cancel the
Silence
function.
SILENCE Function
LED
LED
Clean
5s
5s
Turbo
Press 2 times during one second under the
HEAT
Mode and setting temperature of
62°F/17°C or 20°C (for model of RG10B10(B)/BGEF).
The unit operates at a high fan speed (while the compressor is on)
with the temperature automatically
set to 46°C/8°F.
Press this button 2 times during one second under the
HEAT
Mode and setting temperature of
62°F/17°C or 20°C (for model RG10B10(B)/BGEF) to activate the
FP
function. Press
On/Off
,
Sleep
,
Mode
,
Fan
and
Temperature
while operating, cancels this function.
Note:
This function is for the heat pump air conditioner
only
.
2
+
Press
Clean
and
Turbo
at the same time more than
5 seconds to activate
Lock
function.
All buttons will not respond except when pressing
these two buttons for two seconds again to disable locking.