background image

OM-40MAQ-07                                                                            Specifications subject to change without notice.                                                                                         

9

FOLLOW ME Mode

 Press 

FOLLOW

 to activate or deactivate this function. Under this 

setting, the temperature that appears in the remote control is the actual 
temperature at its location. The remote control sends this signal to the 
air conditioner every 3 minutes. This function is 

not available

 in the 

DRY

 and 

FAN

 modes. This function can also be deactivated if:

1. No 

FOLLOW ME

 signal is received by the unit for continuous 7 

min

2. Users adjust the operation mode
3. Users turn off the unit 
4. Users turn off the 

FOLLOW ME

 function

NOTE: 

If 

FOLLOW ME

 is used with the wireless remote controller, 

make sure that the remote’s IR sender is within line of sight of the IR 
receiver of the unit and is within the maximum range of 25 feet of the 
indoor unit. If 

FOLLOW ME

 is de-activated by pressing 

MODE

OFF

 or 

FOLLOW ME

 on the remote, the icon on the remote will 

turn off.

Freeze Protection (FP) Mode

Press 

FP

 for approximately 2 seconds to activate or deactivate the 

freeze protection mode (heating set back). The indoor unit displays 

FP.

NOTE: This function is only available in the heating mode.

Under this function, the unit operates at high fan speed and the coil 
temperature automatically sets to 46°F (8°C). This mode can also be 
deactivated by pressing 

ON/OFF

SLEEP

MODE

FAN

, or either 

TEMP

.

SILENCE Mode 

Press 

SLC

 to activate of deactivate the 

SILENCE

 Mode. Under this 

function, the compressor operates at low frequency and the indoor 
unit produces a faint breeze, which reduces the noise to the lowest 
level. Due to low the frequency operation of the compressor, it may 
result in insufficient cooling and heating capacity.

LED Light 

Press 

LED

 to turn the display light on and off.

Resetting the Remote Control

If the batteries in the remote control are removed, the current settings 
will be canceled and the control returns to the initial settings and 
enters the 

STANDBY mode

. Push 

ON/OFF

 to activate.

Time Delay

If 

ON/OFF

 is pressed too soon after a stop, the compressor will not 

start for 3 to 4 minutes due to the inherent protection against frequent 
compressor cycling. The unit only emits an audible beep when the 
signals are received correctly.

Heating Features

If the unit is in 

HEATING

 mode, there is a delay when the fan starts. 

The fan starts only after the coil is warmed up to prevent cold blow.

Auto Defrost Operation

In the 

HEATING

 mode, if the outdoor coil is frosted, the indoor fan 

and outdoor fan turns off while the system removes the frost on the 
outdoor coil. The system automatically reverts to normal operation 
when frost is removed from the outdoor unit.

Auto Start

If the power fails while the unit is operating, the unit stores the 
operating condition, and it will start operation automatically under 
those conditions when the power is restored.

Refrigerant Leakage Detection

The indoor unit displays 

EC

 and the indication lamps continue 

flashing when it detects a refrigerant leak.

FP

FAN/SLC

LED

Содержание 40MAQ

Страница 1: ...convenience please record the model and serial numbers of your new equipment in the spaces provided This information along with the installation data and dealer contact information will be helpful sho...

Страница 2: ...on multi zone applications could set an indoor unit to STANDBY mode indicated with two dashes on the display which will turn off the indoor unit until all the indoor units are in the same mode COOLIN...

Страница 3: ...TEMPERATURE SELF DIAGNOSTIC CODES INDICATOR DEFROST INDICATOR Illuminates when the coil is warming up to prevent cold blow or when the unit goes into defrost mode OPERATION INDICATOR This indicator fl...

Страница 4: ...n sleeping hours TURBO Enables unit to reach preset temperature in shortest time possible TEMP Increases temperature in O 1 F 1 C increments Max temperature is O 86 F TEMP Decreases temperature in O 1...

Страница 5: ...F Displays when TIMER OFF is set SLEEP Battery FRESH SILENT ECO Displays when SLEEP function is activated FOLLOW ME Indicates that the FOLLOW ME function is on FAN SPEED Displays selected FAN SPEED HI...

Страница 6: ...t NOTE When transmitting a command from the remote control to the unit be sure to point the control toward the right side of the unit The unit confirms receipt of a command by sounding an audible beep...

Страница 7: ...is lower than the room temperature Selecting the Fan Speed Fig 8 Fan Speeds 1 Press FAN to select the fan speed NOTE When the unit is on the fan runs continuously in cooling or heating When in heatin...

Страница 8: ...Set TIMER OFF as previously described The unit starts automatically at the set TIME ON and turns off at the set TIME OFF SLEEP Mode SLEEP mode is used to conserve energy and can be used when the unit...

Страница 9: ...tivate the SILENCE Mode Under this function the compressor operates at low frequency and the indoor unit produces a faint breeze which reduces the noise to the lowest level Due to low the frequency op...

Страница 10: ...mild detergent Fig 17 Clean the filter 6 Rinse the filter with fresh water then shake off excess water 7 Dry it in a cool dry place and refrain from exposing it to direct sunlight 8 When dry re clip t...

Страница 11: ...ct an authorized service representative if a problem arises that cannot be easily resolved Do not perform cleaning or maintenance activities while the unit is on Keep the display panel on the unit awa...

Страница 12: ...Tightening Clean Fan Wheel Check Fan Tightening Clean Drain Pans PROBLEM POSSIBLE CAUSE SOLUTION Unit System Does Not Work The circuit breaker has tripped or a fuse has blown Diagnostic lights illumin...