– 1
7
–
6. SPECIFICATIONS OF ELECTRICAL PARTS
6-1. Indoor Unit
6-2. Outdoor Unit
No.
1
Reactor
L = 10mH, 16A
2
Outdoor fan motor
DC140V, 43W
3 Suction temp. sensor (TS sensor)
10k
Ω
(25°C)
4 Discharge temp. sensor (TD sensor)
62k
Ω
(20°C)
5 Outside air temp. sensor (TO sensor)
10k
Ω
(25°C)
6 Heat exchanger temp. sensor (TE sensor)
10k
Ω
(25°C)
7
Terminal block (6P)
20A, AC250V
38NYV050M
38NYV060M
9
COIL FOR P.M.V.
DC12V
10 Coil for 4-way valve
AC220-240V
CAM-MD12TF-10
STF
Compressor
3-phases 4-poles 1100W
(Inverter attached)
(Inverter attached)
(Inverter attached)
8
(Inverter attached)
DA130A1F-27F
DA150A1F-20F
Parts name
Model name
Rating
CH-57
ICF-140-43-4R
No.
Fan motor
42NQV060M
(for indoor)
2 Room temp. sensor (TA-sensor)
10k
Ω
at 25°C
3
Heat exchanger temp. sensor (TC-sensor)
10k
Ω
at 25°C
4 Louver motor
Output (Rated) 1W, 16 poles, DC12V
(
−
)
(
−
)
MP24Z3T
ICF-340-30-2
*
DC-340V,30W
Parts name
1
Specifications
Type
42NQV050M