Item
13. Romote-A or B
selection
Operation flow and applicable data, etc.
Description
1. Purpose
This operation is to operate only one
indoor unit using one remote controller.
2. Description
When operating one indoor unit in a
situation where two indoor units have
been installed in the same room or
nearby rooms, this operation prevents the
remote controller signal from being
received simultaneously by both units,
thus preventing both units from operating.
3. Operation
The indoor unit on which the remote
controller selection has been set to B
receives the signal of the remote control-
ler also set to B.
(At the factory the remote controller
selection is set to A on all the indoor
units. There is no A setting display.)
Setting the remote controller
To separate using of remote control for each indoor
unit in case of 2 air conditioner are installed nearly.
Remote Control B Setup.
1) Press RESET button on the indoor unit to turn
2) Point the remote control at the indoor unit.
3) Push and hold button on the Remote
Control by the tip of the pencil. "00" will be shown
the air conditioner ON.
shown on the display.
4) Press during pushing . "B" will
show on the display and "00" will disappear and
the air conditioner will turn OFF. The Remote
Control B is memorized.
Note : 1. Repeat above step to reset Remote Control
to be A.
2. Remote Control A has mot "A" display.
3. Default setting of Remote Control from
factory is A.
−
44
−
FILE NO. SVM-07013
"B" Display
"00" Display