8
−
FILE NO. SVM-
10035
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit
SWT-77
DC 7V, 12V
No.
Parts name
Type
Specifications
1 Fan motor (for indoor) ICF-340-30-2B DC 340V, 30W
2 Thermo sensor (TA-sensor) 10k at 25 C
3 Switching Transformer (T01)
4 Microcontroller unit (IC15)
TMP87CM40ANG-6P68
5
Heat exchanger sensor
10k at 25 C
(TC-sensor)
6 Line filter (L01)
LC*SS11V-R06270 27mH, 600mA
7 Bridge rectifier (DB01) D3SBA60
4A, 600 V
8 Capacitor (C03)
EKMH451VSN121MQ35S 120
m
F, 450 V
9 Fuse (F01) BET6.3A
T6.3A, 250VAC
10 Varistor (R09, R10) SR561K14DO 560 V
11 Resistor (R01 ) RF-5TK1R8 1.8 , 5 W
12 Louver motor MP24Z3T 12VDC
W
W
W
°
°
4-2. Outdoor Unit
Output (Rated) 1500W, 2poles, 1 phase, 220
−
240V, 50Hz
1
Compressor
PA200X2CS-4KU1 Winding resistance
(
Ω
)
Red-Black
White-Black
(at 20
°
C)
1.
85
2.
62
Output (Rated)
42
W,
4
poles, 1 phase, 220 – 240V, 50Hz
2
Fan motor (for outdoor)
FG-240-42A-1
Winding resistance
(
Ω
)
Red-Black
White-Black
(at 20
°
C)
128
126
3
Running capacitor
DS451305NPQB AC 450V,
3.0
µ
F
(for fan motor)
4
Running capacitor
B32332I5606J063
AC 450V,
50
µ
F
(for compressor)
5
Solenoid coil
VHV (STF)
AC 220
−
240V
(for 4-way valve)
6
Thermo sensor TE / TD
10k
Ω
at 25
°
C / 50k
Ω
at 25
°
C
7
Magnetic contactor
A23T
220
−
240V, 50Hz
8
Transformer
TT-05
220
−
240V
9
Microcomputer
TMP47C840N
No. Parts name
Type
Specifications
10
Varistor (R73, R74)
15G471K
470V
11
Fuse (F01)
TSCR
T6.3A, 250V