![Carrier 38BYG Series Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/carrier/38byg-series/38byg-series_product-data_2563152015.webp)
15
048-30
CC5A/CD5AW060
47,000
TDR
—
12.00
—
10.40
48,000
3.26
32,200
2.46
8.0
CE3AA060
47,000
TDR
—
12.00
—
10.40
48,000
3.60
32,400
2.62
8.0
COILS + 58MVP100-20 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
46,000
TDR
—
11.50
—
10.05
48,000
3.46
32,200
2.54
8.0
CC5A/CD5AW060
47,000
TDR
—
12.00
—
10.40
48,000
3.26
32,200
2.46
8.0
CE3AA060
47,000
TDR
—
12.00
—
10.40
48,000
3.44
32,200
2.56
8.0
CK3BA060
47,000
TDR
—
12.50
—
10.80
48,000
3.68
31,800
2.66
8.0
CK5A/CK5BA060
47,000
TDR
—
12.50
—
10.80
48,000
3.46
32,200
2.54
8.0
CK5A/CK5BT060
47,000
TDR
—
12.50
—
10.80
48,000
3.68
31,800
2.66
8.0
CK5A/CK5BX060
47,000
TDR
—
12.00
—
10.55
48,000
3.68
31,800
2.66
8.0
COILS + 58MVP120-20 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
46,000
TDR
—
11.50
—
10.05
48,000
3.46
32,200
2.54
8.0
CC5A/CD5AW060
47,000
TDR
—
12.00
—
10.40
48,000
3.26
32,200
2.46
8.0
CE3AA060
47,000
TDR
—
12.00
—
10.40
48,000
3.44
32,200
2.56
8.0
CK3BA060
47,000
TDR
—
12.00
—
10.35
48,000
3.58
32,400
2.60
8.0
CK5A/CK5BA060
47,000
TDR
—
12.00
—
10.35
48,000
3.58
32,400
2.60
8.0
CK5A/CK5BT060
47,000
TDR
—
12.00
—
10.35
48,000
3.58
32,400
2.60
8.0
CK5A/CK5BX060
47,000
TDR
—
12.00
—
10.60
48,000
3.58
32,400
2.60
8.0
060-30
*FK4DNB006
59,000
TDR&TXV
12.00
—
—
10.30
60,000
3.40
39,000
2.46
8.0
CC5A/CD5AA060
55,000
NONE
—
—
11.00
9.45
60,000
2.94
39,000
2.24
7.0
CC5A/CD5AW060
57,000
NONE
—
—
11.40
9.75
60,000
3.08
38,500
2.30
7.4
CE3AA060
57,000
NONE
—
—
11.50
9.75
60,000
3.12
39,000
2.32
7.4
CK3BA060
55,000
NONE
—
—
11.00
9.65
60,000
3.06
39,000
2.30
7.0
CK5A/CK5BA060
55,000
NONE
—
—
11.00
9.65
60,000
3.06
39,000
2.30
7.0
CK5A/CK5BT060
55,000
NONE
—
—
11.00
9.65
60,000
3.06
39,000
2.30
7.0
CK5A/CK5BX060
57,000
NONE
—
—
11.50
9.85
60,000
3.18
39,000
2.36
7.4
F(A,B)4BN(F,B,C)060
56,500
TDR
11.00
11.00
—
9.50
60,000
3.22
39,500
2.36
7.5
F(A,B)4BN(F,B,C)060
56,500
TDR
—
11.20
—
9.50
60,000
3.16
40,000
2.32
7.5
FB4BNB070
58,000
TDR
—
11.50
—
9.80
60,000
3.30
39,500
2.38
7.7
FC4CN(F,B)060
56,500
TDR&TXV
11.20
—
—
9.50
60,000
3.16
40,000
2.32
7.5
FC4CNB070
58,000
TDR&TXV
11.50
—
—
9.80
60,000
3.30
39,500
2.38
7.7
FG3AAA060
55,500
NONE
—
—
11.30
9.60
60,000
3.04
39,000
2.30
7.3
COILS + 58CV(A,X)110-22 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
54,500
TDR
—
11.30
—
9.75
60,000
2.96
38,500
2.28
7.2
CE3AA060
56,500
TDR
—
11.50
—
10.05
60,000
3.16
38,500
2.38
7.5
CK3BA060
54,500
TDR
—
11.50
—
9.90
60,000
3.28
39,000
2.40
7.5
CK5A/CK5BA060
54,500
TDR
—
11.50
—
9.90
60,000
3.28
39,000
2.40
7.5
CK5A/CK5BT060
54,500
TDR
—
11.50
—
9.90
60,000
3.28
39,000
2.40
7.5
CK5A/CK5BX060
56,500
TDR
—
12.00
—
10.20
60,000
3.30
38,500
2.44
7.5
COILS + 58CV(A,X)135-22 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
54,500
TDR
—
11.30
—
9.70
60,000
2.96
38,500
2.28
7.2
CC5A/CD5AW060
54,500
TDR
—
11.50
—
10.00
60,000
3.14
38,500
2.36
7.5
CE3AA060
56,500
TDR
—
11.50
—
10.05
60,000
3.16
38,500
2.38
7.5
CK3BA060
54,500
TDR
—
11.50
—
9.85
60,000
3.28
39,000
2.40
7.5
CK5A/CK5BA060
54,500
TDR
—
11.50
—
9.85
60,000
3.28
39,000
2.40
7.5
CK5A/CK5BT060
54,500
TDR
—
11.50
—
9.85
60,000
3.28
39,000
2.40
7.5
CK5A/CK5BX060
56,500
TDR
—
12.00
—
10.20
60,000
3.30
38,500
2.44
7.5
COILS + 58CV(A,X)155-22 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
54,500
TDR
—
11.50
—
9.80
60,000
2.98
38,500
2.28
7.2
CC5A/CD5AW060
54,500
TDR
—
11.50
—
10.10
60,000
3.16
38,500
2.36
7.5
CE3AA060
56,500
TDR
—
11.50
—
10.10
60,000
3.18
38,500
2.38
7.5
CK3BA060
54,500
TDR
—
11.50
—
9.95
60,000
3.28
38,500
2.42
7.5
CK5A/CK5BA060
54,500
TDR
—
11.50
—
9.95
60,000
3.28
38,500
2.42
7.5
CK5A/CK5BT060
54,500
TDR
—
11.50
—
9.95
60,000
3.28
38,500
2.42
7.5
CK5A/CK5BX060
56,500
TDR
—
12.00
—
10.25
60,000
3.30
38,500
2.44
7.5
UNIT
SIZE-
SERIES
INDOOR
UNIT
ARI STANDARD RATINGS*
Cooling
Heating
TC
Seasonal Efficiency SEER
EER
High-Temp
Low-Temp
Seasonal
Efficiency
HSPF
Factory-
Supplied
Enhance-
ment
Standard
Rating
Field-Supplied
Accessory
TXV**
TXV & TDR**
TC
COP
TC
COP
* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:
Cooling Standard:
80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.
High-Temperature Heating Standard:
70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.
Low-Temperature Heating Standard:
70°F (21°C) db indoor entering air temperature and 17°F (–8°C) db 15°F (11°C) wb air entering outdoor
unit.
† Outdoor section/indoor section combination tested in accordance with DOE test procedures for heat pumps. Ratings for other combinations are
determined under DOE computer simulation procedures.
‡ Requires hard shutoff TXV; based on computer simulation.
** TDR is provided on most Carrier Furnaces.
COP — Coefficient of Performance
HSPF — Heating Seasonal Performance Factor
SEER — Seasonal Energy Efficiency Ratio
TC
— Total Capacity (Btuh)
TDR
— Time-Delay Relay
TXV
— Thermostatic Expansion Valve
Combination ratings continued
Содержание 38BYG Series
Страница 35: ...35...