Fig. 2—38BRC060 208/230v, 1 Phase, 60 Hertz

A98017

CH (NOTE #9)

RED or BLK

BLK

208/230 1Ø

POWER

SUPPLY

L1

L2

EQUIP

GND

CONT

11 21

13 23

YEL

OFM

YEL

COMP BLU

BRN

BRN

YEL

S

C

R

YEL

YEL

BLU

BLU

BRN

*SC

BLK

BLK

*ST

*SR

1 2

5

CAP

*LPS

*DTS

*HPS

BLK

BLK

YE

L

BLU

VIO

H

C

F

CONNECTION DIAGRAM

+t

°

BLU

BLK

BLU

YE

L

*CTD

BRN

(NOTE #14)

BLU

BLU

BLK

*LLS

BLK

Y

R

G

INDOOR THERMOSTAT (NOTE #5)

INDOOR BLOWER MOTOR

EXTERNAL POWER 
SUPPLY 24V
(NOTES #3 & #6)

(NOTE #8)

FACTORY POWER WIRING
FACTORY CONTROL WIRING
FIELD CONTROL WIRING
FIELD POWER WIRING
COMPONENT CONNECTION
FIELD SPLICE
JUNCTION

CONT CONTACTOR
CAP

CAPACITOR (DUAL RUN)

*CH

CRANKCASE HEATER

*CHS

CRANKCASE HEATER SWITCH

COMP COMPRESSOR
*CTD

COMPRESSOR TIME DELAY

*DTS

DISCHARGE TEMP. SWITCH

*HPS

HIGH PRESSURE SWITCH

IFR

INDOOR FAN RELAY

*LLS

LIQ. LINE SOLENOID VALVE

*LPS

LOW PRESSURE SWITCH

OFM

OUTDOOR FAN MOTOR

*SC

START CAPACITOR

*SR

START RELAY

*ST

START THERMISTOR

*  MAY BE FACTORY OR FIELD

INSTALLED.

-LEGEND-

SCHEMATIC DIAGRAM

(LADDER FORM)

11

21

CONT

L1

QUIP

GND

*SR

*SC

5

2

1

H

C
F

*ST

OFM

+t

°

CONT

23

13

CAP

S

C

R

COMP

L2

*LPS

*DTS

*HPS

CONT

IFR

EXTERNAL POWER SUPPLY 24 V

*CTD

(NOTE #14)

Y

G

R

OOR THERMOSTAT

R C

*CH

-NOTES-

1. Symbols are electrical representation only.
2. Compressor and fan motor furnished with inherent thermal

protection.

3. To be wired in accordance with National Electric N.E.C.

and local codes.

4. N.E.C. class 2, 24 V circuit, min. 40 VA required, 60 VA on

units installed with LLS.

5. Use copper conductors only.
6. Connection for typical cooling only thermostat, for other

arrangements, see installation instructions.

7. If indoor section has a transformer with a grounded

secondary, connect the grounded side to the BRN lead.

8. When start relay and start capacitor are installed, start

thermistor is not used.

9. CH not used on all units.

10.If any of the original wire, as supplied, must be replaced,

use the same or equivalent wire.

11.Check all electrical connections inside control box for

tightness.

12.Do not attempt to operate unit until service valves have

been opened.

13.Do not rapid cycle compressor. Compressor must be off

3 minutes to allow pressures to equalize between high 
and low side before starting.

14.Wire not present if HPS, LPS, DTS or CTD are used.

15.Use conductors suitable for at least 75

°

C (167

°

F).

324474-101 REV. A

. Compressor damage may occur if system is over charged.
. This unit is factory charged with R-22 in accordance with the amount shown on the rating plate. The charge is

 adequate for most systems using matched coils and tubing not over 15 feet long. The best performance will be 
achieved when the unit operates with a suction gas superheat at the compressor inlet of 5 

°

F at normal rating 

conditions of the air conditioning and refrigeration institute (ARI). This chart may be used to approximate the 
charge if ARI rating conditions cannot be obtained. ARI rating conditions are equivalent to DOE test "A"
conditions. See product data literature for required indoor air  flow rates and for use of line lengths over 15 Ft.

. Carefully relieve  refrigerant pressure within this unit before final disposal.

CAUTION

LOGIC

T1

T3

T2

IFR

C
R

*LLS

LOGIC

T1

T3

T2

*CHS

RED or BLK

BLK

*CHS

2