Selecting the Heat or Cool Mode

 

2-Pipe Operation

9

Cool Only 

Step #6 = 2 in the Advanced Setup section, page 19.

Cooling Only 

The 

COOL

 setting indicates the temperature  

that the room has to rise to before the cooling 
source will turn on to cool the room.

Time Schedule for Heating or Cooling 

Program On

 will activate the stored timer  

operation for the heating and cooling 
setpoints (occupied or unoccupied periods).

OFF

 

OFF

 indicates both heating and cooling  

are turned off.

Press

MODE

Press

MODE

Fan

Fan

Downloaded from 

ManualsNet.com

 search engine

Содержание 33CSSP3-FC

Страница 1: ...Owner s Manual Downloaded from ManualsNet com search engine ...

Страница 2: ...rdance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense This Class A digital apparatus meets all the requirements of the Canadian Interference Causing Equipment Regulations Cet appareil...

Страница 3: ...ode Fan AUTO COOL HEAT 1 Liquid Crystal Display withThermoglow 2 Up Down Buttons 3 Mode Button 4 Fan Override Button 5 Heat or Cool Indicator Heat Red Cool Green 1 3 2 4 5 Downloaded from ManualsNet com search engine ...

Страница 4: ...e varies PROGRAM ON Indicates the time period program is enabled to run OFF Indicates heating and cooling are turned off 2 Clock with Day of theWeek Page6 Indicates the current time and day This clock is also used to program the time period schedules 3 RoomTemperature Display Indicates current room temperature 4 Desired SetTemperature Page11 Indicates desired room temperature s OUTSIDE 3 1 2 4 1 1...

Страница 5: ...er Occupied 1 2 3 or Unoccupied 7 Setup icons Pages18 22 Indicates the thermostat is in the advanced setup mode 8 Fan icon Page11 Indicates fan operation Fan low speed Fan medium speed Fan high speed When only the Fan icon is displayed the fan is in the Auto mode and will run only when necessary to heat or cool OUTSIDE 8 6 7 5 Downloaded from ManualsNet com search engine ...

Страница 6: ... programming occupied time periods 10Locked icons Pages30 Indicates keypad has been locked 11Outside icons Pages21 31 Indicates the temperature displayed is from the optional outside sensor OUTSIDE 9 10 11 Downloaded from ManualsNet com search engine ...

Страница 7: ...AN button and press the UP or DOWN button Press the MODE and FAN buttons at the same time to return to normal operation Thethermostatispreprogrammedfromthefactorytooperatea4pipesystemwithout theneedforfurtherprogramming Tooptimizetheinstallationofthisthermostatfora 2pipesystem followtheinstructionsintheAdvancedSetupsection Page19 FAN FAN MODE MODE SettingtheClock SettingtheDay MODE Press To adjust...

Страница 8: ...l ing source will turn on to cool the room Heating or Cooling AUTO will automatically select heat or cool based on room temperature demand Time Schedule for Heating or Cooling Program On will activate the stored timer operation for the heating and cooling setpoints occupied or unoccupied periods Off OFF indicates both heating and cooling are turned off Press MODE Press MODE Press Press MODE MODE F...

Страница 9: ... room has to fall to before the heating source will turn on to heat the room Time Schedule for Heating or Cooling Program On will activate the stored timer operation for the heating and cooling setpoints occupied or unoccupied periods OFF OFF indicates both heating and cooling are turned off Press MODE Press MODE Fan Fan Downloaded from ManualsNet com search engine ...

Страница 10: ... room has to rise to before the cooling source will turn on to cool the room Time Schedule for Heating or Cooling Program On will activate the stored timer operation for the heating and cooling setpoints occupied or unoccupied periods OFF OFF indicates both heating and cooling are turned off Press MODE Press MODE Fan Fan Downloaded from ManualsNet com search engine ...

Страница 11: ...TO will automatically select heat or cool based on the room temperature demand Ifstep 6 3 onlyheatorcoolwillappear Program On will activate the stored timer op eration for the heating and cooling setpoints OFF indicates both heating and cooling are turned off Note Ifthewatertemperatureischangedduring theyear thethermostatwillthenautomatically lockouttheincorrectmode Press MODE Press MODE Press Pre...

Страница 12: ... the buttons Pressing the FAN button will run the fan in low medium or high speed continuously seebelowandpage28 When only the Fan icon is displayed the fan is in the Auto mode and will run only when necessary to heat or cool seebelowand page28 Note IfthethermostatisplacedintheOffmode thefanwillde energize seepage7 Fan Fan Fan Fan FAN Fan Press FAN Press FAN Press FAN Press FAN Press Fan Low Speed...

Страница 13: ...on for 5 seconds will temporarily force the thermostat into Occupied 1 comfort settings for one to six hours step 13 page21 The Override icon will be illuminated during this time If you press and hold the FAN button while the thermostat is currently overriding the daily schedule this will reset the timer return ing the thermostat to the correct time period program for the day Occupied Operation Pr...

Страница 14: ...ximum of occupied periods to be used on any one day Typically most installations use only Occupied 1 1 2 or 3 Adjust the cooling setpoint for Occupied 1 35 99 OF Adjust the heating setpoint for Occupied 1 OF 35 99 Adjust the cooling setpoint for unoccupied periods 35 99 OF Press MODE Press MODE Press MODE Press MODE Continued Downloaded from ManualsNet com search engine ...

Страница 15: ... Select day of the week for Occupied 1 Mo Su Adjust the start time for Occupied 1 Adjust the stop time for Occupied 1 Select Occupied 1 to run on this day On or not to run on this day Off Continued On Off Press MODE Press MODE Press MODE Press MODE Press MODE Downloaded from ManualsNet com search engine ...

Страница 16: ... of the week for Occupied 1 Tu Mo Adjust the start time for occupied 1 Continued Yes No SelectingYes then pressing mode selected will copy the previous day s program and then will ask the same copy question again If yes is selected each time this routine will repeat until Saturday is copied to Sunday After Saturday is copied to Sunday the copy command is unavailable MODE Press IfYes is selected If...

Страница 17: ...points and start stop times for additional occupied periods will be prompted SelectYes or No to copy the pre vious day s program to this day Yes No On Off SelectingYes then pressing mode will copy the previous day s program and then will ask the same copy question again If yes is selected each time this routine will repeat until Saturday is copied to Sunday After Saturday is copied to Sunday the c...

Страница 18: ...amwillrunfrom12 00amMTWTFto8 00amMTWTFandagainfrom 9 00pmMTWTFto12 00pmMTWTF The Unoccupied settings take effect at all times when 1 the program is on and 2 the current time is outside a preset occupied period For this reason start and stop times aren t necessary for unoccupied If the same start and stop times are programmed in for an occupied period then it will run 24 hours If one occupied perio...

Страница 19: ...cedSetupscreens NOTE Eachstep islocated atthetoprightcornerofthe displayforeasyreference MODE FAN DisplayOn DisplayOff Adjust the time of day Tip Tochangehoursquickly pressandholdtheFAN buttonandpresstheUPor DOWNbuttons Select the day of the week Setup Setup Setup ON Press MODE Press MODE Press MODE Continued Downloaded from ManualsNet com search engine ...

Страница 20: ...ectric heat no HotWater only Electric Heat Continued MODE Press MODE Press MODE Press Step 6onlyappearsifstep 5 2 2 PIPE SYSTEM OPERATION Note 3 4requireaccessorychangeoversensor Note WhenSingleSetpointisselected theheatingor coolingsetpointwillalwaysbedisplayed Todisplaytheroomtemperature pressandholdtheMODEbuttonfortwoseconds Thedegreeiconwillblink whenthelargenumberisdisplayingroomtemperaturean...

Страница 21: ...t backlight operation On Light continuously Off Light for 8 seconds after a button press On Off On Off Selectoperationwhen fanisintheAutomode On continuouslowspeedfan Off onlyenergizeduring aheatingorcoolingcycle SeePage28 Note 2 Setup Setup Setup OFF OFF AUTO COOL HEAT Setup MODE Press MODE Press MODE Press MODE Press Continued Downloaded from ManualsNet com search engine ...

Страница 22: ...e wil be active during the unoccupied time period 0 06 hours Dry Contact NO Normally Open NC Normally Closed SeePage26 MODE Press MODE Press MODE Press MODE Press Continued Select thermostat operation in degrees Fahrenheit or Celsius C F Setup Setup Setup Override Setup OUTSIDE OFF Sensor Reading Downloaded from ManualsNet com search engine ...

Страница 23: ...upied when the Dry Contact is closed the thermostat will control to the Unoccupied setpoints Off when the Dry Contact is closed the thermostat will turn off Select Dry Contact operation Occupied the thermostat will enter the Occupied mode when the Dry Contact is closed Unoccupied the thermostat will enter the Unoccupied mode when the Dry Contact is closed Step 16onlyappearsifstep 15 Unoccupied Set...

Страница 24: ...n 1 5 1 7 Fan Auto Operation On Off Off 8 Deadband Temp Swing 1st Stage 1 6 2 9 Minimum Heat Cool Differential 0 6 2 10 Thermoglow Backlight On Off Off 11 Fahrenheit or Celsius F C F 12 Read Only Duct Sensor On Off Off 13 OverrideTimer Length 0 6 hours 2 hours 14 Dry Contact Polarity NO NC NO 15 Dry Contact Operation Occupied Unoccupied Occupied 16 Dry Contact Setpoints Unoccupied Off Unocupied Do...

Страница 25: ...is complete press the MODE button once to save your changes and return to normal operation MODE MODE MODE CALIBRATION Under normal circumstances it will not be necessary to adjust the calibration of the temperature sensor If calibration is required please contact a trained HVAC technician to correctly perform the following procedure OFF OUTSIDE CLOCK BACKUP In the event of a power loss the thermos...

Страница 26: ...tep 8 page20 plusthe2ndstagedead band This 2nd stage deadband is fixed at one degree and is not adjustable The high speed fan for heat or cool is turned on when The temperature spread from the setpoint is equal to or greater than thesetpointplusthe1st stagedeadband step 8 page20 plusthe2ndstagedeadband plusthe3rd stagedeadband This 3rd stage deadband is fixed at one degree and is not adjustable Th...

Страница 27: ...ostat is programmed for Unoccupied operation step 15 page22 the thermostat will be forced into Unoccupied setpoints and the Unoccupied icon will appear on the display Note ThethermostatmustbeinProgramOnmodeforthisfeaturetohaveany effect ImportantNote Forcontrolofmultiplethermostatsbyonesource referto PotentialPhasingProblems onpage32 Connectwirestoatimeclockor otherdevicetoforcethethermostat intoO...

Страница 28: ...manently lost 1 Place the thermostat in the OFF mode 2 Press and hold the MODE button While holding the MODE button press and hold the DOWN button for 5 seconds All icons will appear on the display 3 After all of the icons appear release the MODE and DOWN buttons Then press and hold the FAN button for 5 seconds 4 After the letters Fd appear on the display Factory Default release the FAN button Pre...

Страница 29: ...ff mode or a dry contact forced unoccupied time period see page 26 Notes 1 If a Duct sensor is connected to this thermostat then the fan should be programmed for continuous operation step 7 page 20 This will provide airflow over the Duct sensor and provide more accurate temperature readings 2 If the fan is programmed for continuous operation step 7 page 20 the low speed fan will run continuously w...

Страница 30: ... closer to each other than the value set in Advanced Setup step 9 on page 20 This minimum difference is enforced during Auto changeover and Program On operation Note To increase the spread between the heating and cooling setpoints in the Auto changeover mode press the MODE button until only the heat setpoint is displayed adjust to the desired setpoint Press the MODE button until only the cool setp...

Страница 31: ...g the MODE button press the UP and DOWN buttons together The LOCKED icon will appear on the display then release the buttons Press all three buttons in the order outlined above for keypad lockout MODE Fan Locked Program On 1 To unlock the keypad press and hold the MODE button While holding the MODE button press the UP and DOWN buttons together The LOCKED icon will disappear from the display then r...

Страница 32: ... interference may cause the sensor to give incorrect temperature readings See the Duct Sensor instructions for further details Digital Sensor High Temp Heat Shrink Tubing Plenum Rated Cable White Black Digital Sensor Plenum Rated Cable White Black OUTSIDE SENSOR To view an Outside Sensor step 12 page 21 enter the Advanced Setup by pressing and holding the MODE button While holding MODE press the F...

Страница 33: ...s possible to encounter transformer phasing problems that will interfere with thermostat operation Connecting transformers that are not phased correctly may result in a direct short which could damage transformers and or the thermostat Phasing problems are likely if the units share a common ground with secondary grounded transformers SOLUTION If possible phase all HVAC units together If phasing is...

Страница 34: ...Printed on recycled paper P N 88 1077 Rev 1 Downloaded from ManualsNet com search engine ...

Отзывы: