SPECIFICATIONS (CONT)
Table 4—Heat Pump
HEAT PUMP
System
Size
24
30
34
34
34
Outdoor Model
25HHA424A003
224ANS030000
25HHA430A003
224ANS036000
25HHA436A003
224APS036000
25HHA436A005
224AES036000
25HHA436A006
224ANS048000
Indoor Model
40MKQB34C--3
40MKQB34C--3
40MKQB34C--3
40MKQB34C--3
40MKQB34C--3
Energy Star
NO
NO
NO
NO
NO
Performance
Cooling Rated Capacity
Btu/h
23,400
28,400
32,600
32,600
32,600
SEER
14
14
14
14
14
EER
11.2
12.2
12.2
12.2
12.2
Heating Rated Capacity
Btu/h
20,200
29,000
33,000
33,000
33,000
HSPF
8.2
8.2
8.2
8.2
8.2
COP
W/W
4.24
4.1
3.94
3.94
3.94
Controls
Wireless Remote Controller (°F/°C
Convertible)
Standard
Standard
Standard
Standard
Standard
Wired Remote Controller (°F/°C Convertible)
Optional
Optional
Optional
Optional
Optional
Operating
Range
Cooling Outdoor DB Min - Max
°F
55~125 (-20°F w /
Low-Ambient Kit)
55~125 (-20°F w /
Low-Ambient Kit)
55~125 (-20°F w /
Low-Ambient Kit)
55~125 (-20°F w /
Low-Ambient Kit)
55~125 (-20°F w /
Low-Ambient Kit)
Heating Outdoor DB Min - Max
°F
17~75
17~75
17~75
17~75
17~75
Cooling Indoor DB Min -Max
°F
64~90
64~90
64~90
64~90
64~90
Heating Indoor DB Min -Max
°F
32~80
32~80
32~80
32~80
32~80
Piping
Total Piping Length**
Ft.
200'
200'
200'
200'
200'
Drop (OD above ID)
Ft.
200'
200'
200'
200'
200'
Lift (OD below ID)
Ft.
65'
65'
65'
65'
65'
Outdoor Pipe Connection Size - Liquid
In.
3/8"
3/8"
3/8"
3/8"
3/8"
Outdoor Pipe Connection Size -
Suction
In.
3/4"
3/4"
7/8"
7/8"
7/8"
Indoor Pipe Connection Size - Liquid*
In.
3/8"
3/8"
3/8"
3/8"
3/8"
Indoor Pipe Connection Size - Suction
In.
3/4"
3/4"
3/4"
3/4"
3/4"
Refrigerant
Type
R-410A
R-410A
R-410A
R-410A
R-410A
Design Pressure
PSIG
550
550
550
550
550
Metering Device
Type B Accurator
Charge
Lb.
7.7
12.1
12.3
12.3
12.3
Outdoor
Coil
Face Area
Sq. Ft.
7.3
12.1
12.1
12.1
12.1
No. Rows
2
2
2
2
2
Fins per inch
20
20
20
20
20
Circuits
3
6
5
5
5
Indoor
Coil
Face Area (sq. ft.)
Sq. Ft.
5.6
5.6
5.6
5.6
5.6
No. Rows
3
3
3
3
3
Fins per inch
18
18
18
18
18
Circuits
12
12
12
12
12
Compressor
Type
Scroll
Scroll
Scroll
Scroll
Scroll
Model
ZP21K5E-PFV-130
ZP24K5E-PFV-130
ZP29K5E-PFV-130
ZP29K5E-TF5-130
ZP29K5E-TFD-130
Electrical
Outdoor Voltage, Phase, Cycle
V/Ph/
Hz
208/230-1-60
208/230-1-60
208/230-1-60
208/230-3-60
460-3-60
Indoor Voltage, Phase, Cycle
V/Ph/
Hz
208/230-1-60
208/230-1-60
208/230-1-60
208/230-1-60
208/230-1-60
Power Supply
Indoor and outdoor units have dedicated power supply
MCA (Outdoor)
A.
16.5
17.2
19
12.8
7.6
MOCP - Fuse Rating (Outdoor)
A.
25
30
30
20
15
MCA (Indoor)
A.
1
1
1
1
1
MOCP - Fuse Rating (Indoor)
A.
15
15
15
15
15
Outdoor
Unit Width
In.
36.9
44.5
44.5
44.5
44.5
Unit Height
In.
31.1
37.1
37.1
37.1
37.1
Unit Depth
In.
14.6
17.1
17.1
17.1
17.1
Net Weight
Lbs.
161
196
197
197
197
Airflow
CFM
1,285
2,615
2,615
2,615
2,615
Indoor
Unit Width Body
In.
33.1
33.1
33.1
33.1
33.1
Unit Height Body
In.
33.1
33.1
33.1
33.1
33.1
Unit Depth Body
In.
11.3
11.3
11.3
11.3
11.3
Net Weight Body
Lbs.
68.6
68.6
68.6
68.6
68.6
Unit Width Grille
In.
37.4
37.4
37.4
37.4
37.4
Unit Height Grille
In.
37.4
37.4
37.4
37.4
37.4
Unit Depth Grille
In.
2.2
2.2
2.2
2.2
2.2
Net Weight Grille
Lbs.
11.0
11.0
11.0
11.0
11.0
Number of Fan Speeds
3
3
3
3
3
Airflow (lowest to highest)
CFM
750/820/1130
750/820/1130
750/820/1130
750/820/1130
750/820/1130
Sound Pressure (lowest to highest)
dB(A)
44/48/53
44/48/53
44/48/53
44/48/53
44/48/53
Air throw Data
Ft.
16
16
16
16
16
* Liquid line needs to be insulated