Flush Volume & Stall Setup
Single Stall Installations
1
2
Blank Access Panel
*
Ø20 sparge pipe
*
Reducer to Ø40
copper pipe (supplied)
400mm - 420mm
Frame
45mm
335mm
to
access panel
centre line
Centre Line Button
(standard mounting)
Finished Floor Level
Refer to specifications of the selected urinal.
90mm Min.
Cavity Depth
(70mm Min. for
inceiling
installations)
5mm Min.
45mm Max.
Cladding Thickness
*
*
SIngle Remote Button
950mm
Recommended
Datum
Adjustment
Screw
1.8L = Single Stall Urinal
The cistern is configured for single stall installations out of the factory.
The pneumatic tube must be connected to the full flush position.
By adjusting the water level in the cistern up or down using the float
adjustment screw located on the side of the inlet valve, the flushing
volume may be fine tuned or reconfigured to any of the following flush
volumes.
2.3L = Single Stall Urinal
1.8L = Single Stall Urinal
1.3L = Single Stall Urinal
0.8L = Single Stall Urinal
= Full Flush Position
6
Configuring Flush Volume
Remove Dust Cover and adjust Water
Level using the adjustment screw.
The Water Level should be set to
correspond to your required flush
volume marked on the inside of the
cistern.
Dust Cover
NOTE:
When installing the
Remote Mounting Box in
this position, please refer
to the ‘Installation Note’ on
page 5