GAS CREPE MAKER

Instructions for Gas Conversion:

  MODEL SERIES  382GCM16

                                                                            Warning

Improper installation, adjustment, alteration, service or maintenance can cause 

property damage, injury or death. Read the installation, operating and maintenance instructions 

thoroughly before installing or servicing equipment.
This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s 

instructions and all applicable codes and requirements of the 

authority having jurisdiction. If the information in these instructions is not followed 

exactly, a fire, an explosion or production of carbon monoxide may result causing 

property damage, personal injury or loss of life. The qualified service agency is 

responsible for the proper installation of this kit. The installation is not proper and 

complete until the operation of the converted appliance is checked as specified in the manufacturer’s 

instructions supplied with the kit.

Specific Instructions :

                                                                          CAUTION

ENSURE THE GAS SUPPLY IS SHUT OFF AT THE MANUAL SHUT OFF VALVE BEFORE PROCEEDING WITH THE 

CONVERSION

Switch off the gas at the main supply valve and allow the unit to cool down before commencing with the 

conversion.

Take off the front panel to expose the pilot valve and control valve.

Change the orifice for main burner:

Loosen and remove the brass orifice located on the end of the burner with a wrench.

Replace with the new orifice from the conversion kit, first applying a small amount of jointing paste to the 

thread on the end of the nozzle holder, this will ensure a good gas tight seal.
Adjust the gas regulator:    From NAT Gas to LP Gas:
1. 

Use a 22mm wrench to remove the conversion cap from the top of the regulator.

Содержание 382GCM16LP

Страница 1: ...GAS CREPE MAKER www CarnivalKingSupplies com Item 382GCM16LP LPG 382GCM16N NAT 02 2018 user manual ...

Страница 2: ...le locations only Do not place combustible or non combustible material in the vicinity of the unit as this could cause fires or obstruct airflow to the burner For your protection we recomend a competent intallation agency install this appliance Do not use an appliance that is damaged leaking or which does not operate properly Do not cover or change the primary air supply apertures in the burner as...

Страница 3: ...le threads of the pipe joints Such compounds must be resistant to the action of LP gases MANUAL SHUT OFF VALVES A manual shut off valve should be installed upstream from the manifold and within 4 ft of the unit in a position where it can be reached in the event of an emergency GAS CONVERSION Conversion from Propane to Natural Gas or vice versa may only be performed by the factory or its authorized...

Страница 4: ...s The cooking plate may smoke during this period but this is completely normal Add approximately one tablespoon of cooking oil onto the centre of the hot griddle the flame should be turned to LOW Spread the cooking oil over the entire surface carefully using a rolled up cotton cloth leave the oil to cook for around 5 10 minutes and repeat the process using less oil everytime 6 8 times A well seaso...

Страница 5: ... responsible for the proper installation of this kit The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit Specific Instructions CAUTION ENSURE THE GAS SUPPLY IS SHUT OFF AT THE MANUAL SHUT OFF VALVE BEFORE PROCEEDING WITH THE CONVERSION Switch off the gas at the main supply valve ...

Страница 6: ...ater solution is recommended for locating gas leakage Matches candle flame or other sources of ignition shall not be used for this purpose 2 Put back the front panel and fasten it by screws 3 Fix the conversion rating plate supplied in the kit adjacent to the original rating plate on the rear of the unit Fill in the details required on the installation plate and fix to the surface of the unit 2 Re...

Страница 7: ... Warranty This warranty does not apply to any warranty claims made on products sold or used outside of the United States Residential use voids this warranty 7 Instruction for Normal Operating Sequence Burner Operation To start main burners turn the burner valve knob to ON position then press the igniter Derating at altitudes above 2000 ft 610m Ratings of gas utilization equipment are based on sea ...