Troubleshooting & specifications
........................................................................
Never try to repair or dismantle this product yourself.
Power supply: 230V~ 50Hz
Cooling capacity: 10000Btu/hr
Air volume (max speed): 290m /h
Power input: 1100W
Refrigerant type: R407C/500g
Recommended room size: up to 20m
Timer: 1-23.5hrs
Duct length: 2m
Tank size: 2.8L
Cooling range: 17 - 30
Dehumidifying range: 13 - 30
Net weight: 33kgs
Dimension: 480x840x400
(WxHxD)
we continually strive to improve our products,
specifications may change without notice.
Specifications
3
2
Decrease the set temperature.
1. Unit does not
Start when
Pressing the Power
button
- Water full indicator blinks, water tank
is full.
Empty the water in
the water tank.
Troubles
Possible Causes
Suggest Remedies
Reset the temperature.
Make sure all the windows
and doors are closed.
Remove the heat sources
if possible.
Connect the duct and make
sure it can function properly.
Clean the air filter.
- Room temperature is lower than
the set temperature.(Cooling mode)
- The windows or doors in the room
are not closed.
- There are heat sources inside the
room.
- Exhaust air duct is not connected or
blocked.
- Temperature setting is too high.
- Air filter is blocked by dust.
2. Not cool enough
Place the unit on a flat, level
ground if possible.
It is normal.
- The ground is not level or not flat
enough.
- The sound comes from the flowing
of the refrigerant inside the
air-conditioner.
3. Noisy or Vibration
4. Gurgling Sound