Carlson HydroStar Скачать руководство пользователя страница 2

CAUTION! READ THIS NOTICE BEFORE USING SOFTWARE

Please  read  the following Software License Agreement  before  using  this software package. Using this software indicates

that you have accepted its terms and conditions.

SOFTWARE  LICENSE AGREEMENT

This agreement is between Carlson Software and me.

I promise not to change the software and not to let anyone else use it without Carlson Software's written permission.

I promise not to copy the software except for backup. I will keep a record of all copies I make and upon request let Carlson
Software see it.

I promise to do my best to keep unpermitted copies from being made, and I will destroy any copies I no longer want.

I understand that this is a single user /single system license. If I want to use the software on a different system, except in
emergency,  I understand another agreement must be signed, and allowing my copy to be used by anyone else is a breach of
this agreement.

Carlson Software  assumes  no responsibility to anyone for any special, consequential, collateral or incidental damages in
connection with or arising from the use of this software.

I agree Carlson Software can make changes in the software without letting me know and without giving them to me.

I promise not to modify any copyright, or trademark notice in the software, and  agree to protect Carlson Software from and
reimburse Carlson Software for, any loss if I do such modification.

If I change the software without Carlson Software permission, I understand I lose all rights to make any claims against
Carlson Software. In any event, I understand I must make any claims I wish to make in writing within 90 days after I receive
the software.

I agree the most Carlson Software could ever owe me would be a full refund of whatever amount I paid for the software. I
understand: the laws of the State of Kentucky will govern the interpretation of our Agreement; it is our only agreement about
the software; and if part of this agreement turns out to be invalid, the rest will remain in full force.

Copyright

 

1996-1999 Carlson Software

All Rights Reserved

Содержание HydroStar

Страница 1: ...HydroStar Manual Version 2 0 December 6 1999 Carlson Software 102 West Second Street Suite 200 Maysville KY 41056 606 564 5028 617 254 5429...

Страница 2: ...Software assumes no responsibility to anyone for any special consequential collateral or incidental damages in connection with or arising from the use of this software I agree Carlson Software can ma...

Страница 3: ...to the two GPS receivers mounted on the barge The two receivers on the barge are attached by serial cable to the computer running HydroStar HydroStar uses the centimeter accurate positions from the tw...

Страница 4: ...tical points on the barge the two GPS antennas and the pile driver or depth sounder The barge must be drawn correctly in order to appear correctly in HydroStar The barge should be drawn so that GPS An...

Страница 5: ...rees to radians multiply by 0 017453 The second measurement is the distance from GPS1 to the center of the pile placed by the pile driver This measurement should be in the same units your project is i...

Страница 6: ...le All points are stored in the coordinate file Click on this button to change the current file or create a new one The coordinate file is stored in the Data directory RMS Tolerance RMS is a measureme...

Страница 7: ...o Load Last Alignment With this set to Yes HydroStar will always use the last alignment points This saves you the trouble of re aligning every day but your base must be set up the same each time See t...

Страница 8: ...y response from the receiver will be displayed Please refer to the GPS receiver docu mentation for descriptions of these additional receiver commands Simulation Mode To run HydroStar without being hoo...

Страница 9: ...int alignment is useful for data collection on a new site In this case you can set the GPS base receiver up anywhere convenient Then position the rover GPS 1 over the first point and runAlign Local Co...

Страница 10: ...Northing Easting Elev HRes VRes HV 5000 00 5000 00 993 50 0 0 0 0 YY 5324 52 4739 43 970 23 0 0 0 0 YY 1 Add 2 Del 3 View 4 On 5 Load X eXit LAT LON Elev HRMS VRMS HV 41 153943 83 031243 992 87 0 03...

Страница 11: ...ELEV These are the local coordinates if a local alignment is defined Otherwise these are the state plane coordinates The Solution Status is one of the following Too Few Satellites The GPS receiver is...

Страница 12: ...oad Actual Grid File This can be left with nothing selected Load Plan View File This is the drawing showing the plan view of the site It is used only as a visual aid for you HydroStar does not take an...

Страница 13: ...g Easting and Elevation when prompted If the point you want already exists in your coordinate file pick By Point Number and enter the point number of this point To do By Station and Offset you must ha...

Страница 14: ...ns and is calculating an accurate position If the status is FLOAT the reciever is picking up some information from the base but is not fully sure of its true position If the status is AUTONOMOUS the r...

Страница 15: ...HydroStar to PCMCIA Card The routines apply to computers that have a PCMCIA drive The drive letter for the PCMCIA drive on the computer should be specified under the Options menu The program will dis...

Страница 16: ...e depth reported by the sounder from the GPS elevation The Rod Height setting in General Options should show the height difference between the GPS1 antenna and the zero point for the depth sounder The...

Страница 17: ...ht Gray 15 White Plan View Example POLYLINE 15 47639 82 74540 11 0 00 47670 49 74565 79 0 00 47701 08 74591 49 0 00 49375 61 76358 47 0 00 50066 86 76846 75 0 00 POLYLINE 15 47633 24 74547 97 0 00 476...

Отзывы: