Carlos mendoza ambar Скачать руководство пользователя страница 7

2.3

    SETTING UP WITH A DMX512 

         CONTROLLER

2.3-1  DMX512 ADDRESSING WITHOUT ID ADDRESSING
           (STUDIO 2 MODE)

The figure above shows a simple DMX512 

layout with the starting address of the first 

unit set at 1, with the second set at 7 and 

so on...  (Note that when used in this way,

the CH6 ID function must be  inactive (CH6=0))

DMX512

CONTROLLER

 

Connect the DMX512 controller to the units in series.  

 

Each unit has 6 DMX channels so the DMX Addresses should increase by increments of 

   6 (e.g. 1,7,13,19...)

The ID address has not been set so therefore when using the controller CH8 must 

   be inactive ( CH6=0 ).

It is also possible to deactivate ID address selecting

ID OFF

from the

Settings

menu.

   on the fixture 

 

Each DMX Address may be used as many times as required.

 

Any DMX address in the range from 001 to 512 may be used.

2.3-2  DMX512 ADDRESSING WITH ID ADDRESS (STUDIO 2 MODE)

 

Connect the DMX512 controller to the units in series

 

Each unit has 6 DMX channels so the DMX Addresses should increase by increments of 

   6 (e.g. 1,7,13,19...)

 

Each DMX Address may be used as many times as required.

 

Any DMX address in the range from 001 to 512 may be used.

 

Each DMX address may carry up to 66 separate ID addresses.

 

ID

should be set in the menu on each unit in ascending values

    (i.e. 1,2,3...)

 

ID On

should be set in the

Settings

menu on each unit.

 

ID addresses are accessible from CH6 on the DMX512 controller.

Example:

2 INSTALLATION

............

DMX Addr.1

DMX Addr.7

DMX Addr.13

2008.9.19

www.carlosmendoza.com.mx - (55) 56 72 85 69 - 72*15*18765

Содержание ambar

Страница 1: ...LEDbloc USER MANUAL Blanco ambar www carlosmendoza com mx...

Страница 2: ...WHITES SETTING 9 PART 1 PRODUCT GENERAL 1 1 1 PRODUCT INTRODUCTION 1 1 2 PRODUCT FEATURES 1 1 3 TECHNICAL SPECIFICATIONS 2 1 4 PHOTOMETRIC DATA 3 1 5 SAFETY WARNING 3 PART 2 INST ALLATION 4 2 1 MOUNT...

Страница 3: ...rol Direct input of DMX512 signal allows the units to be controlled from any DMX512 controller This product can be operated as a single unit or in multiple units for large applications 1 2 PRODUCT FEA...

Страница 4: ...65 protection rating 54pcs 42 x White 12 x Amber Weight LED Unit Output LED Cooling IP 1W Direct air convection 380 x 200 x 190mm 8Kg 100 240V 50 60Hz 80W 1 PRODUCT GENERAL 2 Environment Temperature 2...

Страница 5: ...e wet ATTENTION This product left the place of manufacture in perfect condition In order to maintain this condition and for safe operation the user must always follow the instructions and safety warni...

Страница 6: ...should also be used 220V 35 units may be connected in series 120V 15 units may be connected in series The LED MODULEcan be mountedat any angleand in any position It ispossible to furtheradjust the an...

Страница 7: ...F from the Settings menu on the fixture Each DMX Address may be used as many times as required Any DMX address in the range from 001 to 512 may be used 2 3 2 DMX512 ADDRESSING WITH ID ADDRESS STUDIO 2...

Страница 8: ...he user to collectively control the whole group of units at that DMX address by setting CH6 to 0 or to control each unit independently by first selecting the DMX address and then by using Ch6 to locat...

Страница 9: ...through the main menu or return to the main menu 3 DISPLAY PANEL OPERATION 2008 9 19 SET UP DOWN MODE MODE 3 DISPLAY PANEL OPERATION 7 3 2 MENU MODE White Amber Strobe STATIC COLOR 0 255 0 255 Address...

Страница 10: ...the DMX mode to set the DMX ADDRESS RUN MODE Enter the RUN MODE mode to set working mode DMX mode is for using the DMX512 controller to control the fixtures SLAVE mode is for Master Slave operation N...

Страница 11: ...isplay WHITE In order to reset custom modes to default values select PESET Parameter Enter ID ON OFF in order to allow disallow ID address function from the DMX512 controller SETTING Upload RESET Para...

Страница 12: ...It is possible to have the same DMX address or independent addresses for each fixture 4 2 CHANNEL ASSIGNMENT 10 4 USING A DMX512 CONTROLLER 2008 9 19 4 USING A DMX512 CONTROLLER WA 1 2 0 255 CHANNEL...

Страница 13: ...4 3400K WHITE 5 4200K WHITE 6 4900K WHITE 7 5600K WHITE 8 5900K DIFFERENT WHITES NO FUNCTION 0 9 10 255 1 20Hz STROBE 5 ID ADDRESS ID1 ID66 ID1 ID2 ID3 ID4 ID5 ID6 ID7 ID8 ID9 ID10 ID11 ID12 ID13 0 9...

Страница 14: ...mum CH2 and CH3 can be combined together to create whites with different color temperature STROBE CH 5 controls the strobe of CH1 to CH4 CH5 has priority over CH2 CH3 CH4 DIFFERENT WHITES Ch4 allow us...

Страница 15: ...uttons damaged 2 Main PCB damaged 1 Replace buttons 2 Replace Main PCB 1 Signal Cable error 2 Signal conncetion error 3 The inputsignal IC damaged4 DMX address error Display normal but no response fro...

Страница 16: ...APPENDIX PLASTIC UPPER COVER LENS COMPLETE SET DRIVER BOARD DISPLAY BOARD BRACKET PLASTIC BASE COVER POWER SUPPLY POWER SUPPLY COVER METAL BASE LED BOARD 2008 9 19 Version 1 0 1 2 3 4 5 6 7 8 9 10 ww...

Отзывы: