1.4

    PHOTOMETRIC DATA

1 PRODUCT(GENERAL)

3

2008.9.19

1.5

    SAFETY WARNING

IMPORTANT

ALWAYS READ THE USER MANUAL BEFORE OPERATION.   

PLEASE CONFIRM THAT THE POWER SUPPLY STATED ON THE

    PRODUCT IS THE SAME AS THE MAINS POWER SUPPLY IN YOUR 

    AREA.

 

This product must be installed by a qualified professional.

 

Always operate the equipment as described in the user manual.

A minimum distance of 0.5m must be maintained between the equipment and    

combustible surface.

 

The product must always be placed in a well ventilated area.

  

Always make sure that the equipment is installed securely.

DO NOT stand close to the equipment and stare directly into the LED light  

source.

  

Always disconnect the power supply before attempting and maintenance.

 

Always make sure that the supporting structure is solid and can support the 

combined weight of the products.

 

The earth wire must always be connected to the ground.

 

Do not touch the power cables if your hands are wet.

ATTENTION

 

This product left the place of manufacture in perfect condition.  In order to 

maintain this condition and for safe operation, the user must always follow the 

instructions and safety warnings described in this user manual.

 

Avoid shaking or strong impacts to any part of the equipment.

 

Make sure that all parts of the equipment are kept clean and free of dust.

 

Always make sure that the power connections are connected correct and    

secure.

 

If there is any malfunction of the equipment, contact your distributor 

immediately.

 

When transferring the product, it is advisable to use the original packaging in 

which the product left the factory.

 

Shields, lenses or ultraviolet screens shall be changed if they have become 

damaged to such an extent that their effectiveness is impaired.

 

The lamp (LED) shall be changed if it has become damaged or thermally 

deformed.

WHITE

1

2

3

0

1

2

3

2

4

6

8

10Distance(m)

3338

900

410

247

166  LUX

15

AMBER

WHITE+AMBER

1

2

3

0

1

2

3

2

4

6

8

10Distance(m)

1261

361

155

90

62  LUX

15

1

2

3

0

1

2

3

2

4

6

8

10Distance(m)

4795

1270

567

331

226  LUX

15

www.carlosmendoza.com.mx - (55) 56 72 85 69 - 72*15*18765

Содержание ambar

Страница 1: ...LEDbloc USER MANUAL Blanco ambar www carlosmendoza com mx...

Страница 2: ...WHITES SETTING 9 PART 1 PRODUCT GENERAL 1 1 1 PRODUCT INTRODUCTION 1 1 2 PRODUCT FEATURES 1 1 3 TECHNICAL SPECIFICATIONS 2 1 4 PHOTOMETRIC DATA 3 1 5 SAFETY WARNING 3 PART 2 INST ALLATION 4 2 1 MOUNT...

Страница 3: ...rol Direct input of DMX512 signal allows the units to be controlled from any DMX512 controller This product can be operated as a single unit or in multiple units for large applications 1 2 PRODUCT FEA...

Страница 4: ...65 protection rating 54pcs 42 x White 12 x Amber Weight LED Unit Output LED Cooling IP 1W Direct air convection 380 x 200 x 190mm 8Kg 100 240V 50 60Hz 80W 1 PRODUCT GENERAL 2 Environment Temperature 2...

Страница 5: ...e wet ATTENTION This product left the place of manufacture in perfect condition In order to maintain this condition and for safe operation the user must always follow the instructions and safety warni...

Страница 6: ...should also be used 220V 35 units may be connected in series 120V 15 units may be connected in series The LED MODULEcan be mountedat any angleand in any position It ispossible to furtheradjust the an...

Страница 7: ...F from the Settings menu on the fixture Each DMX Address may be used as many times as required Any DMX address in the range from 001 to 512 may be used 2 3 2 DMX512 ADDRESSING WITH ID ADDRESS STUDIO 2...

Страница 8: ...he user to collectively control the whole group of units at that DMX address by setting CH6 to 0 or to control each unit independently by first selecting the DMX address and then by using Ch6 to locat...

Страница 9: ...through the main menu or return to the main menu 3 DISPLAY PANEL OPERATION 2008 9 19 SET UP DOWN MODE MODE 3 DISPLAY PANEL OPERATION 7 3 2 MENU MODE White Amber Strobe STATIC COLOR 0 255 0 255 Address...

Страница 10: ...the DMX mode to set the DMX ADDRESS RUN MODE Enter the RUN MODE mode to set working mode DMX mode is for using the DMX512 controller to control the fixtures SLAVE mode is for Master Slave operation N...

Страница 11: ...isplay WHITE In order to reset custom modes to default values select PESET Parameter Enter ID ON OFF in order to allow disallow ID address function from the DMX512 controller SETTING Upload RESET Para...

Страница 12: ...It is possible to have the same DMX address or independent addresses for each fixture 4 2 CHANNEL ASSIGNMENT 10 4 USING A DMX512 CONTROLLER 2008 9 19 4 USING A DMX512 CONTROLLER WA 1 2 0 255 CHANNEL...

Страница 13: ...4 3400K WHITE 5 4200K WHITE 6 4900K WHITE 7 5600K WHITE 8 5900K DIFFERENT WHITES NO FUNCTION 0 9 10 255 1 20Hz STROBE 5 ID ADDRESS ID1 ID66 ID1 ID2 ID3 ID4 ID5 ID6 ID7 ID8 ID9 ID10 ID11 ID12 ID13 0 9...

Страница 14: ...mum CH2 and CH3 can be combined together to create whites with different color temperature STROBE CH 5 controls the strobe of CH1 to CH4 CH5 has priority over CH2 CH3 CH4 DIFFERENT WHITES Ch4 allow us...

Страница 15: ...uttons damaged 2 Main PCB damaged 1 Replace buttons 2 Replace Main PCB 1 Signal Cable error 2 Signal conncetion error 3 The inputsignal IC damaged4 DMX address error Display normal but no response fro...