Examples:
4, 0, 0, means a setting of 400 mm.
With this setting of the switches to
the left on the front plate, SP1 is set
to 400 mm.
C, 5, 5, means a setting of 1255 mm
(hex “C” = decimal “12”).
With this setting of the switches to
the right on the front plate, SP2 is set
to 1255 mm.
The setting of the setpoints determines the polarity of the analogue out-
put function. See “LIMITS” - function switch 1.
Function switches 1-4
Switch 1:
LIMITS / SETPOINTS
OFF: Output is in the range of 0....2000 mm (programmable).
The analogue output signal is in the range of 150 to 2000 mm.
ON:
Selectable polarity of the analogue output slope:
Positive slope when SP1 < SP2. SP1 defines the zero point (0 V
or 4 mA) and the shortest distance. SP2 defines the final value
(10 V or 20 mA) and the longest distance.
Negative slope when SP2 < SP1. SP1 defines the zero point (0 V
or 4 mA) and the longest distance. SP2 defines the final value
(10 V or 20 mA) and the shortest distance. See the following
drawing.
0 1
2
3