10
INTRODUCTION
This user manual must be read
and completely understood, prior
to carrying out any operation on
the module, by personnel dealing
with all the activities of the
NLG13D724..
safety module.
All the operations described in this
manual must be carried out exclu-
sively by specialised personnel by
carefully following all the indica-
tions given.
The module are named
“
NLG13D724xx
” where “
xx
” speci-
fy each model of the family.
This manual is referred to the
models with not-monitored manual
START function (”SA”), monitored
manual START function (”SC”) and
to the respective plug-in versions
(”DA” and “DC”)
The user decides under his com-
plete resposability that the safety
module is suited for the application.
FUNCTION
The safety module
NLG13D724..
is designed to be employed in
safety circuits to control
ElectroSensitive Protective
Equipments (ESPE) with static
PNP outputs or relay outputs
according to 98/37/EC and
2006/42/EC Machinery Directives.
NOTE
The input terminals of the module
are intended to be:
“
operated
” when the light beams
are not interrupted, the ESPE and
the module are correctly supplied
and there are not fault conditions
of the safety system: the ESPE
outputs are ON, the module is
enabled to close the safety out-
puts and the external contactors
can be energized.
“
released
” when the light beams
are interrupted, or the ESPE
and/or the module are not correc-
tly supplied or there are fault con-
ditions of the safety system: the
ESPE outputs are OFF, the
module is not enabled to close
the safety outputs and the exter-
nal contactors cannot be energi-
zed.
INSTALLATION
W
ARNING
- The safety module must be
installed following the standards
in force in the country of use,
when the machine is not powe-
red and with no dangers for the
operator, on the machine’s elec-
trical board in a dry and clean
place (minimum protection
degree: IP54), fixed on the spe-
cial DIN rail.
- If the safety module is tampered
with, it can not ensure the safety
of the operator any more and
the warranty is void.
- To avoid interference due to
coupling, run the connecting