4. OPERATING MODE

With manual START configuration,

the safety outputs close, if S1 & S2

are operated, when the N.O.

START pushbutton is pushed. With

Automatic START configuration,

the safety outputs close as soon as

both S1 & S2 switches are operat-

ed. The Channel 1 & Channel 2

LED turn on.

Opening even one input contact

(S1 and/or S2) leads to a safety

condition for the operator, forcing

immediately the safety outputs to

an open status. The LED relative

to the channel whose input has

been opened turns off.

A new operating cycle is possible

only after opening both input con-

tacts and then closing them (and

pushing the START button, if the

safety module has been set up

with Manual START configuration).

In the model with monitored manu-

al START set up, if the N.O.

START button gets welded, the

safety outputs cannot close their

contacts any more.

5. TEST & ACTIVATION

The following operations must be

repeated when the module is

installed and every time the wiring

is changed and at regular intervals

by carrying out 

in sequence all

the

steps described below without any

type of dangerous condition for the

operators.

STEP 1

Check the integrity, the

correct installation, the correct

positioning on the machine and the

correct functioning of all the

devices connected to the inputs

and to the outputs of the 

NA12D

safety module. Check also the cor-

rect wiring of all the devices (See

3.2).

STEP 2

Power on the safety mod-

ule: the 

POWER

LED turns on (this

LED has to be considered ON in all

the steps of this sequence). The

CHANNEL1

and 

CHANNEL2

are

off.

Close the input contacts: the safe-

ty outputs are open and the

CHANNEL1

&

CHANNEL2

are off

(if the module is configured for

automatic START,

CHANNEL1

&

CHANNEL2

turns on and the safe-

ty outputs close).

Close the START contact: the

safety outputs close and the

CHANNEL1

,

CHANNEL2

LED

turn on.

STEP 3

Open both input contacts:

the safety outputs open and the

CHANNEL1

,

CHANNEL2

LED

turn off.

During  STEP 2 check that the

safety outputs do not close - with

manual START configuration - sim-

ply closing both input contacts,

without closing the START push-

button.

5

Содержание NA12D

Страница 1: ...User manual User manual SAFETY SAFETY MODULE MODULE NA12D NA12D...

Страница 2: ...3 INSTALLATION 3 3 1 Warning 3 3 2 Wiring 3 3 3 Power supply 3 3 4 Input 4 3 5 START Circuit 4 3 6 Safety Outputs 4 4 OPERATING MODE 5 5 TEST ACTIVATION 5 6 USAGE PRECAUTIONS 6 7 INSPECTIONS AND MAINT...

Страница 3: ...se when the machine is not powered and with no dangers for the operator on the machine s electrical board in a dry and clean place minimum protection degree IP54 fixed on the spe cial DIN rail If the...

Страница 4: ...d automatic manual START Also the version with monitored manual START is available The first model can be employed con necting between the X1 X2 termi nals either a N O START push button for not monit...

Страница 5: ...e the wiring is changed and at regular intervals by carrying out in sequence all the steps described below without any type of dangerous condition for the operators STEP 1 Check the integrity the corr...

Страница 6: ...e out puts technical data Never in any situation connect spark quenching unit circuits in parallel to safety outputs contacts the safety function would no longer be guaranteed Never in any circumstanc...

Страница 7: ...0 V DC 300 V Max Switching Current 6 A Max Switching Power Resistive Load 1380 VA Output contacts protection External fuse 4 A delayed 5A fast Mechanical Life 107 switching cycles Electrical Life with...

Страница 8: ...61000 6 2 EN 61000 6 3 Operating temperature 20 65 C Storage Temperature 25 65 C Relative operating humidity 10 95 Relative storage humidity 10 95 Cross Section of the cables to connect to the termina...

Отзывы: