background image

1. INTRODUCTION

This user manual must be read

and completely understood, prior

to carrying out any operation on

the module, by personnel dealing

with all the activities of the 

NA12D

safety module. The instructions

refer to the models configured

either for controlled manual

START or for not-controlled manu-

al/automatic START.

All the operations described in this

manual must be carried out exclu-

sively by specialised personnel by

carefully following all the indica-

tions given.

The user decides under his com-

plete resposability that the safety

module is suited for the application.

2. FUNCTION

The safety module 

NA12D

can be

employed in safety circuits to con-

trol E-STOP pushbutton and limit

switch devices, according to

98/37/CE Machinery Directive.

3. INSTALLATION

3.1 Warning

• The 

NA12D

safety module must

be installed following the stan-

dards in force in the country of

use, when the machine is not

powered and with no dangers for

the operator, on the machine’s

electrical board in a dry and

clean place (minimum protection

degree: IP54), fixed on the spe-

cial DIN rail.

• If the safety module is tampered,

it can not ensure the safety of the

operator any more and the war-

ranty is void.

• To avoid interference due to cou-

pling, run the limit switches con-

necting conductors separately

from the power conductors.

• Avoid installation during storms.

• Do not dispose of the packaging

in the environment.

3.2 Wiring

It is recommended to use conduc-

tors with section and length ade-

quate to the terminals, currents

and distances involved, ensuring

that the conductors are not exces-

sively tight, that their positioning

avoids potential cuts or squashing

and that they are not in the way of

people or things.

3.3 Power supply

Connect the A1 and A2 terminals

to the power supply source.

3

TERM.

CONNECTION

A1

+24VDC / 24VAC

A2

GND / 24 VAC

S11-S12

S21-S22 N.O. Input channels
X-1-X2

Feedback loop and START

terminals

13-14

23-24

N.O. Safety outputs

Tab. 1: Terminal description

Содержание NA12D

Страница 1: ...User manual User manual SAFETY SAFETY MODULE MODULE NA12D NA12D...

Страница 2: ...3 INSTALLATION 3 3 1 Warning 3 3 2 Wiring 3 3 3 Power supply 3 3 4 Input 4 3 5 START Circuit 4 3 6 Safety Outputs 4 4 OPERATING MODE 5 5 TEST ACTIVATION 5 6 USAGE PRECAUTIONS 6 7 INSPECTIONS AND MAINT...

Страница 3: ...se when the machine is not powered and with no dangers for the operator on the machine s electrical board in a dry and clean place minimum protection degree IP54 fixed on the spe cial DIN rail If the...

Страница 4: ...d automatic manual START Also the version with monitored manual START is available The first model can be employed con necting between the X1 X2 termi nals either a N O START push button for not monit...

Страница 5: ...e the wiring is changed and at regular intervals by carrying out in sequence all the steps described below without any type of dangerous condition for the operators STEP 1 Check the integrity the corr...

Страница 6: ...e out puts technical data Never in any situation connect spark quenching unit circuits in parallel to safety outputs contacts the safety function would no longer be guaranteed Never in any circumstanc...

Страница 7: ...0 V DC 300 V Max Switching Current 6 A Max Switching Power Resistive Load 1380 VA Output contacts protection External fuse 4 A delayed 5A fast Mechanical Life 107 switching cycles Electrical Life with...

Страница 8: ...61000 6 2 EN 61000 6 3 Operating temperature 20 65 C Storage Temperature 25 65 C Relative operating humidity 10 95 Relative storage humidity 10 95 Cross Section of the cables to connect to the termina...