CARLO GAVAZZI MC36C Скачать руководство пользователя страница 10

10

Rev.2 | MC36C safety magnetic sensors | © 2022 | 

CARLO GAVAZZI Industri A/S

EN

7. Electrical connections

1

2

3

4

1BN
3BU

2WH
4BK

1

2

3

4

3BU

4BK

1BN

2WH

1

2

3

4

1BN
3BU

2WH
4BK

1

2

3

4

3BU

4BK

1BN

2WH

4BK

1BN

2WH

3BU

4BK

1BN

2WH

3BU

GN

GY

BN

WH

YE

PK

4BK

1BN

2WH

3BU

4BK

1BN

2WH

3BU

GN

GY

BN

WH

YE

PK

1NC + 1NO, plug M8

2NO, plug M8

1NC + 1NO, plug M8 with LED

2NO, plug M8 with LED

1NC + 1NO, cable

2NO, cable

1NC + 1NO, cable with LED

1NC + 2NO, cable

2NO, cable with LED

1NC + 2NO, cable with LED

Содержание MC36C

Страница 1: ...ic sensors Carlo Gavazzi Industri A S Over Hadstenvej 40 8370 Hadsten Denmark EN IT DE FR ES DA ZH Instruction manual Betriebsanleitung Manual de instrucciones Manuale d istruzione Manuel d instructio...

Страница 2: ......

Страница 3: ...n 8 6 Operating and alignment direction 9 7 Electrical connections 10 8 Maintenance and disposal 11 9 Technical data 12 9 1 Electrical data 12 9 2 Outputs 12 9 3 Actuating characteristics 12 9 4 Switc...

Страница 4: ...dicate warning concerning the user and or the safety device Service and warranty In the event of malfunction or requests for information please contact the CARLO GAVAZZI branch or distributor in your...

Страница 5: ...H Reed contact 2O Contacts 2 normally open 1O1C Contacts 1 normally open and 1 normally closed 2O1C Contacts 2 normally open and 1 normally closed L Left exit R Right exit A2 Connection type PVC cable...

Страница 6: ...operated when the corresponding MC36CM actuator is close to the sensor All the MC36CH MC36CM pairs described in this manual make up a multiple flow redundant Type 4 coded system with low level coding...

Страница 7: ...XY plane Z axis e g hinged gate door A correct alignment is achieved when the MC36CH sensor and the MC36CM actuator lay on the same XY plane aligned to the same position X0 see fig 2 In that position...

Страница 8: ...h the use of easily available instruments or objects such as screws nails pieces of metal keys and generally through objects or tools related to the normal machine working operations Based on the indi...

Страница 9: ...switching distance Sao is the one in which all safety contacts have switched their status The Assured switch off distance Sar is the one in which when the actuator moves away from the sensor all safet...

Страница 10: ...BK 1BN 2WH 1 2 3 4 1BN 3BU 2WH 4BK 1 2 3 4 3BU 4BK 1BN 2WH 4BK 1BN 2WH 3BU 4BK 1BN 2WH 3BU GN GY BN WH YE PK 4BK 1BN 2WH 3BU 4BK 1BN 2WH 3BU GN GY BN WH YE PK 1NC 1NO plug M8 2NO plug M8 1NC 1NO plug...

Страница 11: ...H MC36CM pair and in repeating for each sensor actuator pair all the operations concerning the machine start up procedure Maintenance consists of a regular cleaning of the sensor and the actuator and...

Страница 12: ...or sensors without LED Rated operational current Ie 0 25 A resistive load Short circuit proof No Switching frequency 100 Hz Max switching load 6W resistive load Thermal current Ith 0 25 A 9 3 Actuatin...

Страница 13: ...with M12 connector 9 9 Cable version Model Output contact Associated actuator Usage cathegory MC36CH2OxA2 2 NO MC36CM max 4 MC36CH2OxA2L 2 NO MC36CM max 4 MC36CH1O1CxA2 1NO 1NC MC36CM max 4 MC36CH1O1...

Отзывы: