Application Example
Task:
A floor lighting is to switch on automatically for 5 minutes with PIR sensor G 8910 1127 and
also serve as intruder alarm when the house is empty.
Solution:
G 8910 1127 must be connected to the Dupline bus and given an address (here A1). In this
example, increase of the signal transmission time through the DIP switch is to be switched out.
Configure both the object “Motion detector” and an output channel of a relay module for
address A1 and additional objects needed for the intruder alarm (Manual armouring, Alarm
siren).
Also in this case, the motion detector activates the output module for the lighting directly on address A1. If
the alarm system is activated via the manual armouring, the Master Generator generates an alarm within 10 s
after the third impulse.
Additional details about the intruder alarm can be found in chapter 2.4.5.
Tip:
If you want to use the Sabotage protection (Normally closed function) of the G 8910 1127, you should
configure the object “Push button function” for the normally closed function and use the increase of signal
transmission time function provided by the module.
In order to include the detector with sabotage protection in an intruder alarm system, you must use the object
“Active detector” of the intruder alarm system in stead of the Push button function.