INSTALLATION
CAUTION
!
NOTE
WA R N I N G
!
GENERAL INFORMATION
The following section contains general information on the
installation of 9060 High Voltage Controller.
DO NOT
locate the Controller near or adjacent
to heat producing equipment such as ovens, high
wattage lamps, etc.
As each installation is unique, this information is
intended to provide general installation information
for the 9060 Controller. Consult your authorized
Ransburg distributor for specific directions pertaining
to the installation of your equipment.
LOCATION OF THE 9060
Install the Controller in an area
outside the hazardous
location
in accordance with federal, state, and local codes.
The area should protect the Controller from the possibility
of environmental intrusion (such as dust or moisture), have
ambient temperatures that do not exceed 40°C, and be as
close to the applicator as possible to minimize the length
of the high voltage cable.
AC INPUT CONNECTIONS
For non-conduit installations, plug the detachable AC line
cord into the receptacle on the side of the 9060 Controller.
Plug the other end of the line cord into a properly grounded
120 volt AC outlet.
For those installations where it is required to run the AC
input wiring in conduit, perform the following:
1. Ensure the AC line cord is unplugged
and remove
the AC inlet receptacle wiring from TB1-N, TB1-L1 and
TB1-EARTH GROUND (See Figures 5 and 7).
2. Remove the mounting hardware from the AC inlet
receptacle and remove it from the side of Controller.
3. Install the Conduit Adapter Plate (supplied) in the
hole where the AC inlet receptacle was removed (see
Figure 6).
4. Install the AC input wiring (0.8mm
2
(18AWG) minimum)
through the Conduit Adapter Plate using conduit and
wire to TB1 as follows:
The 9060 Controller
MUST
be located outside
of the hazardous area.
The User
MUST
read and be familiar with the
“Safety” section of this manual.
This manual
MUST
be read and thoroughly un-
derstood by
ALL
personnel who operate, clean, or
maintain this equipment! Special care should be tak-
en to ensure that the warnings and requirements of
operating and servicing safely are followed. The user
should be aware of and adhere to ALL local building
and fire codes and ordinances as well as NFPA-33,
OSHA, and all related country safety codes prior to
installing, operating, and/or servicing this equipment.
Only approved applicators should be used with
the 9060 High Voltage Controller.
Hot/Line
to TB1-L1
Neutral/Common to TB1-N
Ground
to TB1-EARTH GROUND
Figure 5: Location of TB1 & TB2 in Controller
CP-13-04.3 (10/2017)
14 / 29
www.carlisleft.com
INSTALLATION