INSTALLATION
EN
AH-13-01-R8 (09/2022)
16 / 55
www.carlisleft.com
NOTE
WARNING
!
WARNING
!
CAUTION
!
Figure 6: Initial Position of Feed Tube and Brush
Item #
Description
1
2
Feed Tube 3700-00 for 4” Bell
Feed Tube 6335-00 for 2 3/4” Bell
Feed Tube 4076-00 for 6” Bell
3695-00 Brush
Figure 7: Installing Bell on Shaft
Replacing the plastic set screw with one of conductive
material (metal) will cause a hazardous condition to exist,
capable of producing an electrical discharge possible of
sparking a fire. In all cases use the plastic screw provided
or provided as a spare part.
4. Re-position the feed tube in the bell cavity at approximately
the 4 to 5 o’clock position. The feed tube should
NOT
rub
on the bell. Adjust the feed tube if necessary, by rotating
it or sliding it forward or backward in the barrel.
Item #
Description
1
2
3
4
No. 2 Motor Shaft
Shaft Locating Flat
Bell Set Screw
Bell
The Bell Cleaning Can provides a convenient and portable
method of removing excess materials from the bell cup at
the conclusion of spray.
ACCESSORY INSTALLATION
Included with the unit are two accessory items:
• Bell cleaning can and the gun holder.
Insure ground line of the bell cleaning can is
attached to true earth ground when either solvent is
stored in the can or the can in use.
Insure any cleaning solvent used meets criteria
listed in the maintenance section of this manual.
The bell and feed tube
MUST
be matched to ensure
proper fluid feed into the bell cavity. The following
chart will assist in selecting the proper bell and feed
tube combination:
Bell Size Feed Tube# Position of Tube
2-3/4”
6335-00
@2 o’clock
4”
3700-00
@4-5 o’clock
6”
4076-00
@4-5 o’clock
The gun holder provides a method to mount and store the
applicator when not in use.
INITIAL POSITION OF FEED TUBE
AND BRUSH
(Figure 6)
INSTALLING BELL ON SHAFT
(Figure 7)
1
2
4
3
2
1