background image

INSTALLATION (continued)

1.  Be sure to read all "Warnings" and "Cau-

tions" in this manual and on the unit before 

installation or using this equipment.

2.  Install filter as close as possible to point 

where air is being used. Install main air 

shut-off  valve  and  standard  pipe  union 

(supplied  by  user)  upstream  of  filter  to 

allow maintenance to unit.

3.  Install  unit  with  air  flow  through  filter 

 

in direction of arrow on top of unit. 

4.  Minimum  1/2"  piping  is  recommended.  

Avoid  using  fittings,  couplings,  etc. 

 

that restrict air flow.

5.  Mount filter in a vertical position.
6.  Do  not  install  filter  in  an  application 

where  the  pressure  drop  will  exceed 

 

20  psi.    For  example,  a  quick  opening 
valve  located  upstream  from  the  filter 
could  cause  a  momentary  pressure 

 

drop in excess of 20 psi.

7.  Maximum  inlet  pressure  and  operating 

temperature is: 150 PSIG (10.3 bar) and 
150° F (65.6° C).

8.  A 6' length of vinyl tubing is shipped loose 

with the unit. Slide over automatic drain 
which protrudes from bottom of bowl. Place 
other end of vinyl tubing into appropriate 
receptable (i.e. below booth grating, can, 
etc.). Prevent vinyl tubing from becoming 
kinked which would prevent free movement 

 

of liquids discharged from the automatic 
drain.

9.  An optional manual drain (HAF-11) can be 

installed in place of the automatic drain.

OPERATION

After the unit is installed and ready to use;

1.  Attach air hose(s) to outlet ball valve(s), 

selecting regulated and/or non-regulated 

according to the application (not supplied).

2.  Open main shut-off valve upstream of filter.

3.  Open ball valve(s) (not supplied) to supply 

air to spray gun or tool being used.

4.  After use, shut off ball valve(s) and bleed 

off residual air in hose(s).

Note

The  filter  change  indicator  only 

operates  when  air  is  flowing.  It 

will always be green when there 

is no flow.

MAINTENANCE

Certain  solvents, paints and 

chemicals may attack plastic 

bowl and can cause bowl failure. 

Do not use near these materials. 

When bowl becomes dirty, wipe 

only with a clean, dry cloth. Im-

mediately replace any crazed, 

cracked, damaged or deteriorated 

plastic bowl with a new plastic 

bowl. Reinstall metal bowl guard.

Risk of injury. Components under 

pressure. Relieve air pressure 

before performing maintenance.

1.  Before  performing  maintenance  on  unit, 

close main shut-off valve located upstream 
of filter. Bleed off residual air in unit.

2.  To  open  filter,  press  button  located  on 

clamp ring and rotate ring either clockwise 

or counterclockwise while pulling down on 

ring. The metal bowl guard and plastic bowl 

can then be removed from the filter head.

3.  Remove  the  filter  element  by  loosen

-

ing    counterclockwise.  Clean  or  replace 

the filter element. Frequency of element 

 

replacement  will depend upon air quality, 
air usage, and condition of the air piping. 
It is recommended to check the element 
change indicator daily, and replace when 
indicator turns red.

4.  Inspect  o-ring  for  damage.  Replace  if 

necessary.

5.  Inspect plastic bowl for signs of damage 

such  as  cracks,  crazing  or  deterioration.   
Replace  if  necessary.  See "Caution" in 
column 2.

Risk of injury. Do not place unit 

in service without metal bowl 

guard installed.

 6.  Before placing unit back into service, make 

sure plastic bowl and metal bowl guard are 
properly  installed  and  securely  locked  in 
place.

7.  Confirm automatic drain operates properly 

after unit  is in operation. Refer to Service 
Bulletin SB-6-149 which provides automatic 
drain service information. Replace if neces

-

sary.

ACCESSORIES

HAF-407

CleanAir™ Mounting Bracket 

Assembly Kit

EN

SB-6-152-R3  (10/2020)

2 / 4

www.carlisleft.com

Отзывы: