Page 8 of 16
77-3290 R1.5
General Description
The MX44046XX-XXX fluid paint pump is designed for pumping High Viscosity
materials such as Mastic, PVC, Underseals, Sound deadeners and other similar
materials.
The fluid section is a ‘ROD’ type design which means the rod displaces the material
and is the only wear contact with the packings. A two-ball check valve system
ensures precise, smooth volume output. Tungsten Carbide ball seats ensure
maximum operating life between servicing.
The interior design maintains high flow capacity with minimum pressure drop
ensuring high efficiency; special surface treatments provide a smooth micro surface
making cleaning and flushing easier.
The piston and rod seals are the chevron type, which can be adjusted by means of
a gland nut, should wear occur, a preloaded wave spring is employed to adjust and
maintain the lower chevron packing preload when wear occurs. A built in Solvent
cup cleans and lubricates the pump rod and seals to prolong working life.
The air motor also utilises the Binks quick exhaust technology to prevent air valve
freezing conditions when high cycle speeds are employed.
The air motor is furnished with an exhaust muffler to control air exhaust noise
emission. An adapter kit is also available to facilitate connection to a piped exhaust
system if required.
Installation
This pump should be flushed with a suitable compatible solvent prior to use.
It is recommended that a propriety 1/2" BSP Filter / Regulator is used to provide
final control of the compressed air to the air motor.
Mount the pump securely and position the pump at a convenient height to allow for
maintenance, visual observation, and periodic inspection.
The Pump Assembly must be connected to a suitable earth ground to ensure that
there is no possibility of static build up.
Attach suitable pipework or flexible hoses designed to meet the working pressure of
the pump assembly (dependent on pump ratio) to the inlet and outlet connections,
e.g. 1½” Inlet/ Ram unit inlet and 1¼” Outlet.
Set the pump speed to a slow cycle rate and start the pump to remove any air from
the fluid circuit. Inspect for any air or fluid leaks.
The Upper Packing Nut should be re-torqued after an initial bedding in period of
approximately 8 hours of operation. See
Preventative Maintenance & Guidance
section for details.
Содержание BINKS MX44046 Series
Страница 1: ...77 3290 R1 5 www carlisleft com Instruction Manual MX44046XX XXX Pump...
Страница 2: ...Page 2 of 16 77 3290 R1 5...
Страница 4: ...Page 4 of 16 77 3290 R1 5...
Страница 5: ...Page 5 of 16 77 3290 R1 5...
Страница 6: ...Page 6 of 16 77 3290 R1 5 MX44046XX CMH MX44046XX SMH...
Страница 7: ...Page 7 of 16 77 3290 R1 5 MX44046XX CMB MX44046XX SMB...
Страница 9: ...Page 9 of 16 77 3290 R1 5 KEY GREASE AGMD 010 LOCTITE TORQUE...
Страница 14: ...Page 14 of 16 77 3290 R1 5 DATE DETAILS OF ADJUSTMENT LUBRICATION ADDED...
Страница 15: ...Page 15 of 16 77 3290 R1 5 DATE DETAILS OF ADJUSTMENT LUBRICATION ADDED...