General Description 

 

 

The  MX44046XX-XXX  fluid  paint  pump  is  designed  for  pumping  High  Viscosity 
materials  such  as  Mastic,  PVC,  Underseals,  Sound  deadeners  and  other  similar 
materials.  

 

The fluid section is a ‘ROD’ type design which means the rod displaces the material 
and  is  the  only  wear  contact  with  the  packings.    A  two-ball  check  valve  system 
ensures  precise,  smooth  volume  output.    Tungsten  Carbide  ball  seats  ensure 
maximum operating life between servicing. 

 

 

The  interior  design  maintains  high  flow  capacity  with  minimum  pressure  drop 
ensuring high efficiency; special surface treatments provide a smooth micro surface 
making cleaning and flushing easier. 

 

The piston and rod seals are the chevron type, which can be adjusted by means of 
a gland nut, should wear occur, a preloaded wave spring is employed to adjust and 
maintain the lower chevron packing preload when wear occurs. A built in Solvent 
cup cleans and lubricates the pump rod and seals to prolong working life. 

 

The air motor also utilises the Binks quick exhaust technology to prevent air valve 
freezing conditions when high cycle speeds are employed. 

 

The  air  motor  is  furnished  with  an  exhaust  muffler  to  control  air  exhaust  noise 
emission. An adapter kit is also available to facilitate connection to a piped exhaust 
system if required.  
 

Installation 

 
This pump should be flushed with a suitable compatible solvent prior to use. 

 

It is recommended that a propriety 1/2" BSP Filter / Regulator is used to provide 
final control of the compressed air to the air motor. 

 

Mount the pump securely and position the pump at a convenient height to allow for 
maintenance, visual observation, and periodic inspection.  

 

The Pump Assembly must be connected to a suitable earth ground to ensure that 
there is no possibility of static build up. 

 

Attach suitable pipework or flexible hoses designed to meet the working pressure of 
the pump assembly (dependent on pump ratio) to the inlet and outlet connections, 
e.g.  1½” Inlet/ Ram unit inlet and 1¼” Outlet. 

 

Set the pump speed to a slow cycle rate and start the pump to remove any air from 
the fluid circuit. Inspect for any air or fluid leaks. 
 
The  Upper  Packing  Nut  should  be  re-torqued  after  an  initial  bedding  in  period  of 
approximately 8 hours of operation. See 

Preventative Maintenance & Guidance

 

section for details. 

 

Содержание BINKS MX44046 Series

Страница 1: ...77 3290 R1 5 www carlisleft com Instruction Manual MX44046XX XXX Pump...

Страница 2: ...Page 2 of 16 77 3290 R1 5...

Страница 3: ...nlet CMH SMH Fluid Inlet CMB SMB Fluid Outlet 1 NPT Ram Inlet 1 NPT Weight 165 Pounds 81 KG Rod Upper Packing Seal Options PU PTFE UHMW PE CG Ceramic filled UHMW PE Glass filled PTFE CL Ceramic filled...

Страница 4: ...Page 4 of 16 77 3290 R1 5...

Страница 5: ...Page 5 of 16 77 3290 R1 5...

Страница 6: ...Page 6 of 16 77 3290 R1 5 MX44046XX CMH MX44046XX SMH...

Страница 7: ...Page 7 of 16 77 3290 R1 5 MX44046XX CMB MX44046XX SMB...

Страница 8: ...prevent air valve freezing conditions when high cycle speeds are employed The air motor is furnished with an exhaust muffler to control air exhaust noise emission An adapter kit is also available to f...

Страница 9: ...Page 9 of 16 77 3290 R1 5 KEY GREASE AGMD 010 LOCTITE TORQUE...

Страница 10: ...3940 FX440 GUARD ADAPTOR 1 11 FX440XX XXX FX440XX XXX FLUID SECTION 1 Pump Accessories PART No DESCRIPTION REMARKS 192506 Exhaust Tube Adapter 1 NB hose For piped exhaust 0114 014178 Earth Wire MXA C1...

Страница 11: ...804 CL Fluid Seal Kit XXB pumps Ceramic UHMW PE Leather Packing Set All O rings All Gaskets Check Main Parts List in Air Motor Fluid Section Manuals for details of individual Kit Contents Recommended...

Страница 12: ...o packing nut by half a turn 180 to relieve pressure on O ring seal 5 Tighten packing nut to 120Nm using tool 502893 and suitable torque wrench 6 Refill Lubricant Cup with approved Lubricant 7 Open is...

Страница 13: ...replace as required Leak from rod seal packings Gland nut not tightened after initial bedding in period a Stop the pump b Close inlet outlet ball valves c Relieve all material pressure d Clean all mat...

Страница 14: ...Page 14 of 16 77 3290 R1 5 DATE DETAILS OF ADJUSTMENT LUBRICATION ADDED...

Страница 15: ...Page 15 of 16 77 3290 R1 5 DATE DETAILS OF ADJUSTMENT LUBRICATION ADDED...

Страница 16: ...om br Tel 55 11 5641 2776 Fax 55 11 5641 1256 WARRANTY POLICY Binks products are covered by Carlisle Fluid Technologies five year materials and workmanship limited warranty The use of any parts or acc...