background image

EN

IMPORTANT! DO NOT DESTROY

READ ALL INSTRUCTIONS BEFORE OPERATING THIS PRODUCT

Service Manual

DE-12, DE-15 Pneumatic Drum Elevator

It is the Customer's responsibility to have all operators and service personnel read and understand this 

manual.

Contact your local Carlisle Fluid Technologies representative for additional copies of this manual.

77-3313 R1.1

www.carlisleft.com

Содержание Binks DE-12

Страница 1: ...Manual DE 12 DE 15 Pneumatic Drum Elevator It is the Customer s responsibility to have all operators and service personnel read and understand this manual Contact your local Carlisle Fluid Technologi...

Страница 2: ...issued under the sole responsibility of the manufacturer Machinery Directive 2006 42 EC ATEX Directive 2014 34 EU by complying with the following statutory documents and harmonized standards EN ISO 1...

Страница 3: ...s worn at all times while equipment is in use PRESSURE RELIEF PROCEDURE Always follow the pressure relief procedure in the equipment instruction manual INSPECT THE EQUIPMENT DAILY Inspect the equipmen...

Страница 4: ...bar 100 psi Agitator controls A Air inlet connection SPECIFICATION Maximum Load 30 Kg 66lb s Stroke DE 15 1500mm 59 B 70 dBA Leq 0 1m s 4 s G1 2 BSPP Female Oil 0 1mg m Water 20 C 7 bar 940 ppm Dirt 5...

Страница 5: ...m 91 5 2818mm 111 1318mm 52 X RH Controls shown 1608mm 63 5 1858mm 73 5 W 1068mm 42 DE 15 Z 2858mm 113 Dimension Y INSTALLATION DE 12 Dimensions in mm inches 3358mm 132 5 77 3313 R1 1 5 16 www carlisl...

Страница 6: ...pply to the air connection Include a pressure relieving isolation valve Locate within 2m 80 Operate the elevator at a low pressure for the first time and adjust speed of operation as specified Ensure...

Страница 7: ...4 5 7 8 9 10 11 1 If fitted If fitted If fitted Air supply Manifold Up Down speed controller E CONTROL PANEL Up pushbutton valve To Pump To Agitator Pump on off valve Agitator on off valve Agitator in...

Страница 8: ...y down position when equipment mounted to it is in use To raise the elevator press the top control panel pushbutton 4 the position can be stopped at any point To lower the elevator press the bottom co...

Страница 9: ...K 16 DEK 17 SPARE PARTS Anti rotation Complete kit DEK 04 Cylinder cap Complete kit 3 4 ITEM 1 DEK 05 Seal and bearing kit 2 DESCRIPTION PART NO DEK 03 Mounting bar kit Piston rod Complete kit 5 77 33...

Страница 10: ...neumatic Agitator switch electric Cover plates Earth cable DEK 33 DEK 34 DESCRIPTION Valve fittings up green Valve fittings down red Valve fittings agitator or pump Cylinder speed controllers Inlet ma...

Страница 11: ...Grease AGMD 010 refer to figure Spanner or socket size Torque Prior to carrying out any maintenance ensure the elevator is in the down position and all air is exhausted from the cylinder prior to the...

Страница 12: ...EN Agitator switch setting MAINTENANCE 77 3313 R1 1 12 16 www carlisleft com...

Страница 13: ...bearings and seals replace as required Lubricate all bearings and seals Check tightness of mounting bar fasteners Check rods for scoring a Adjust to set initial speed b Adjust to set remaining stroke...

Страница 14: ...EN ITEM PART NO DESCRIPTION Bracket fittings ACCESSORIES DEK 42 Coil hose 1 2 DEK 44 DE 12 DE 15 DEK 43 77 3313 R1 1 14 16 www carlisleft com...

Страница 15: ...EN R1 0 R1 1 CHANGE NO DATE DESCRIPTION REV INTRODUCED 04 04 2018 M14901 FOR SERIAL NUMBER 81286 28 05 2019 M15249 NOTES 77 3313 R1 1 15 16 www carlisleft com...

Страница 16: ...sle Fluid Technologies is a global leader in innovative finishing technologies Carlisle Fluid Technologies reserves the right to modify equipment specifications without prior notice DeVilbiss Ransburg...

Отзывы: