background image

INJECTION HAZARD

Spray from the gun, hose leaks, or ruptured components can inject fluid into 

your body and cause extremely serious injury, including poisoning or the need 

for amputation. Splashing fluid in eyes or on skin can also cause a serious injury.
•  Fluid injected into the skin might look like just a cut, but is a serious injury and 

should be treated as such. GET IMMEDIATE MEDICAL ATTENTION. INFORM THE 

PHYSICIAN WHAT TYPE OF MATERIAL WAS INJECTED.

•  Do not point the spray gun at anyone or any part of the body.

•  Do not put fingers or hand over the spray tip.

•  Do not stop or detect fluid leaks with a rag, hand, body or glove.

•  Do not use a rag to blow back fluid. THIS IS NOT AN AIR SPRAY GUN.

•  Engage the gun safety when not spraying.

•  ALWAYS RELIEVE THE PRESSURE WHENEVER WORKING ON THE SPRAY GUN.

•  Tighten all fluid connections before operating equipment.

•  Check all hoses, tubes, and couplings daily. Replace all worn, damaged, or 

loose parts immediately.

Hazardous fluids or toxic fumes can cause serious injury or death if splashed on 

skin or in the eyes, swallowed or inhaled.

TOXIC FLUID HAZARD

•  Know the specific hazards of the fluid you are using. This information is on the 

SDS for the material being used. Read all fluid manufacturer’s warnings.

•  Store hazardous fluids in approved containers only. Dispose of all hazardous 

fluids in accordance with all state, local and national guidelines.

•  Wear the appropriate protective clothing, gloves, eyewear and respirator.

Equipment misuse can cause the equipment to fail, malfunction, or start 

unexpectedly and result in serious injury.

EQUIPMENT MISUSE HAZARD

•  This equipment is for professional use only.

•  Read and understand all instructional manuals, tags, and labels before 

operating equipment.

•  Use the equipment only for its intended purpose. If you are unsure about its 

purpose call your local Binks distributor.

•  Do not alter or modify this equipment. Use only genuine Binks parts.

•  Do not exceed the maximum working pressure of the lowest rated system 

component. THE MAXIMUM RATING OF THE AA1600M IS 1600 PSI (110 BAR) 

FLUID PRESSURE. DO NOT EXCEED THE FLUID PRESSURE RATING.

•  Route all hoses away from all sharp edges, moving parts, hot surfaces and 

high traffic areas.

•  Do not use hoses to pull the equipment.

•  Use only Binks approved hoses. Do not remove spring guards from hoses, 

these are on the hoses to prevent rupture from kinking at the connectors.

•  Use only solvents compatible with hoses and wetted parts of the equipment 

used.

•  Comply with all applicable local state and national fire, electrical, and other 

safety regulations.

Improper grounding, poor air ventilation, open flames, or sparks can cause a 

hazardous condition and result in fire or explosion and cause serious injury.

FIRE AND EXPLOSION HAZARD

•  Ground the equipment and object being sprayed.

•  Provide fresh air ventilation to avoid the build up of flammable fumes from 

the material being sprayed or from solvent.

•  Extinguish all open flames or pilot lights in spray area.

•  Electrically disconnect all equipment in the spray area.

•  Keep the spray area free from all debris, including solvent rags.

•  If there is any static sparking while using the equipment, STOP SPRAYING 

IMMEDIATELY. Identify and correct problem.

NOISE LEVELS

•  The A-weighted sound level of spray guns may exceed 85 dB(A) depending 

on the setup being used. It is recommended that ear protection is worn at all 

times when spraying.

  

WARNING

HIGH PRESSURE CAN CAUSE SERIOUS INJURY IF 

EQUIPMENT IS INSTALLED OR USED INCORRECTLY.

READ, UNDERSTAND, AND OBSERVE

  

ALL WARNINGS AND INSTRUCTIONS  

IN THIS MANUAL.

OPERATE EQUIPMENT ONLY AFTER ALL 

INSTRUCTIONS ARE CLEARLY UNDERSTOOD.

!

FLAMMABLE, EXPLOSIVE AND TOXIC VAPORS

HIGH PRESSURE SPRAY  

AND HOSE LEAKS

In this part sheet, the words 

WARNING

CAUTION

 and 

NOTE

 are used to emphasize important safety information as follows:

 CAUTION

Hazards or unsafe practices which could 

result in minor personal injury, product 

or property damage.

!

   WARNING

Hazards or unsafe practices which could 

result in severe personal injury, death or 

substantial property damage.

!

NOTE

Important installation, operation or 

maintenance information.

Binks reserves the right to modify equipment specification without prior notice.

    WARNING

For pressures over 1000 psi the tip guard must be in place for 

added protection against skin injection.

!

EN

77-2921-R12  (2/2021)

3 / 14

www.carlisleft.com

Содержание Binks AA1600M

Страница 1: ...re 100 psi 6 8 bar Gun Body Forged Aluminum Fluid Path Stainless Steel Fluid Seat UHMW Tungsten Carbide optional Fluid Inlet Size 1 4 NPS m Thread Air Inlet Size 1 4 NPS m Thread Gun Weight 17 28 oz 4...

Страница 2: ...sle Fluid Technologies Machinery Directive 2006 42 EC ATEX Directive 2014 34 EU by complying with the following statutory documents and harmonized standards EN ISO 12100 2010 Safety of Machinery Gener...

Страница 3: ...NOT EXCEED THE FLUID PRESSURE RATING Route all hoses away from all sharp edges moving parts hot surfaces and high traffic areas Do not use hoses to pull the equipment Use only Binks approved hoses Do...

Страница 4: ...y developing pressure standardization charts Repeat step 6 until the required material coverage and spraying speed are achieved If the maximum fluid pressure is reached before the required material co...

Страница 5: ...Air Pressure 14 psi 1 BAR Gun Body Forged Aluminum Alloy Fluid Path Stainless Steel and Tungsten Carbide UHMW PROBLEM CAUSE ACTION Fluid leaking from through the seal Worn seal or needle shaft Loose n...

Страница 6: ...h cleaning The points that need lubrication during the maintenance of air assist airless spray guns include the fluid needle packing and trigger pivot point Gun lube is used to lubricate the fluid nee...

Страница 7: ...igger install the new fluid nozzle and gasket Torque fluid nozzle from 9 to 11 ft lbs See fig 5 5 Replace the air cap along with spray tip See fig 4 REPLACING THE FLUID NEEDLE ASSEMBLY 1 Remove the tr...

Страница 8: ...ge bore with slight resistance due to seal e Rear seal must look clean and in position in the bore See fig 18 f If any of the above cannot be rectified replace the air valve See Replacing Air Valve p8...

Страница 9: ...ervice tool grooves must fit in service tool form See fig 32 8 Push rear seal firmly into hole up to shoulder using Service tool See figs 33 34 9 Insert new spring ensuring the end with the plastic be...

Страница 10: ...the gun until it is fully hand tightened See fig 39 5 Slip on the plastic tip guard onto the air cap in proper orientation See fig 40 6 Place round bar screwdriver approx 12 long between open section...

Страница 11: ...INE FINISH TIP 0 013 13 0 09 9 1315 F FINE FINISH TIP 0 013 15 0 09 9 1509 F FINE FINISH TIP 0 015 9 0 12 9 1511 F FINE FINISH TIP 0 015 11 0 12 9 1513 F FINE FINISH TIP 0 015 13 0 12 9 1515 F FINE FI...

Страница 12: ...ssembled with Retaining ring and appropriate tip guard When switching from flat tip to twist tip or vice versa be sure to order correct fluid seat 3 3A For twist tip item 5B will also be needed Refer...

Страница 13: ...T TIP COMPONENTS X TIGHTEN 9 YO 11 FT LBS Y TIGHTEN 18 TO 22 FT LBS Z DO NOT OVER TIGHTEN 7 z Y X X Y X X Y 9A 7A 5B 54 5891 K5 QTY 5 54 5896 K5 QTY 5 FOR SPRAY GUNS MANUFACTURED AFTER 1 20 2016 6A 6...

Страница 14: ...modify equipment specifications without prior notice BGK Binks DeVilbiss Hosco MS and Ransburg are all registered trademarks of Carlisle Fluid Technologies Inc 2021 Carlisle Fluid Technologies Inc Al...

Отзывы: