EN
77-3139-R2 (1/2019)
3 / 12
www.carlisleft.com
15:1 GEAR DRIVEN AGITATORS FOR 55 GALLON DRUMS WITH EXISTING AGITATOR:
31-451
55 Gallon Agitator Drive with threaded adapter for drums with existing agitator
Before attempting any installation of agitators onto
pressure feed tanks, the tanks must be relieved of
pressure as high pressure can cause a serious injury.
Pressure is maintained in a pressure tank after the
system has been shut down. Before attempting
removal of cover, fill cap, or center plug, pressure
must be relieved using the following steps:
!
WARNING
PRESSURE RELIEF PROCEDURE
(IF USED ON PRESSURIZED TANKS)
1. Turn off the main air supply to the tank.
2. Close air inlet valve located on tank air manifold. Remove
air inlet hose.
3. Bleed off air in the tank by turning the air relief valve
thumb screw counter-clockwise. Wait until all the air has
escaped through the valve before removing the pressure
tank cover, fill cap, or center plug.
4. Leave the air relief valve open until you have reinstalled the
cover, fill cap, or center plug.
AIR SUPPLY
Air supplies (compressors etc.) shall be sited in a non-
hazardous area with a filter on the air intake system to
prevent the ingress of dust or similar foreign materials into the
parts where compression takes place.
OPTIONAL AIR MOTOR LUBRICATION
(Lubrication will extend the life of the motor)
An automatic air line filter/lubricator should be installed in the
air supply line no more than 18” from the air motor. A 5
micron filter is recommended. Install the lubricator level with
or above the motor so the oil mist will blow directly into or
down into the motor (see Fig. 1).
Fill the oil reservoir with SAE 10W motor oil.
Adjust lubricator
to feed 1 drop of
oil for every 50
cfm of air or 1
drop per minute
of continuous
running.
The unit may also
be lubricated
manually by adding 10-20 drops of oil SAE 10 weight oil into
the air inlet fitting at the start of each shift.
Periodically—Remove air adjusting valve and air strainer and
flush motor with a clean suitable solvent. Remove trapped
particles from screen and clean air strainer felt.
Fig 1
MAIN AIR LINE
MUFFLER
AIR MOTOR
FILTER
REGULATOR
LUBRICATOR
ISOLATOR
VALVE
DESCRIPTIONS
15:1 GEAR DRIVEN AGITATORS FOR 55 GALLON OPEN TOP DRUMS:
31-424
55 Gallon Agitator with Stainless Steel Drum Cover
31-397
55 Gallon Agitator with Plated Steel Drum Cover
31-400
Gear Driven Agitator Assembly (less cover)
31-456
Agitator Drive for 31-423, 31-397, and 31-400
41-3305
Agitator only (less drive and less cover)
31-455
Agitator Drive for 30 and 60 Gallon Tanks (Includes 13” air hose and fittings)
15:1 GEAR DRIVEN AGITATORS FOR 55 GALLON DRUMS WITH EXISTING AGITATOR:
31-454
55 Gallon Agitator Drive with bracket hardware for drums with existing agitator
31-453
Replacement Drive for 31-394
31-451
31-424
31-454
31-451
31-424
31-454
31-451
31-424
31-454