Spectra series
Adjustments, settings and alignments
1108 Service
instructions 37
5.8 Angle of aperture (cutter unit)
CAUTION!
Risk of injury, particularly during maintenance, the cutter
blades are sharp!
Figure 20
If the labels show dog-ears after the cutting procedure or if a paper
jam occurred then the angle of aperture (F) is to be increased.
1. Remove the 3 countersink screws (D).
2. Remove the right cover of cutter unit.
The reflexion photocell (C) scans the screw head (B) onto the belt
drive (A).
3. If the angle of aperture is too small, the photocell has to be turned
slightly in clockwise direction.
Loosen the screw (E). Keep the distance of 5 mm between
photocell and screw head.
4. Place the cover onto the spacer pillar in order that the reflexion
photocell is not exposed to extraneous light.
5. Start a number of test cuts.
Verify if the cutter unit effects the cuttings over the complete
passage width.
6. If an uncut margin remains at the right side then the angle of
aperture is too big.
In this case turn back slightly the photocell.
7. Mount again the cover.
Содержание Spectra series
Страница 1: ...Service instructions Label printer Spectra series November 2008 ...
Страница 10: ......
Страница 26: ......
Страница 42: ......
Страница 59: ...Spectra series Wiring plan 1108 Service instructions 59 8 Wiring plan Figure 34 Spectra 107 108 160 162 ...
Страница 60: ...Wiring plan Spectra series 60 Service instructions 1108 Figure 35 Spectra 216 ...
Страница 61: ...Spectra series Layout diagrams 1108 Service instructions 61 9 Layout diagrams 9 1 CPU Figure 36 ...
Страница 63: ...Spectra series Layout diagrams 1108 Service instructions 63 9 2 Power supply unit revision G Figure 37 ...
Страница 70: ......
Страница 74: ......