Technical Data
Dynacode II IP
32
Operating Manual
03.21
Device connection version if 'Option: 2. LED'.
Figure 11
When connecting a reed contact with a control input, the contact must
have a switching capacity of min. 1 A in order to prevent the contact
from sticking due to the inrush current. As an alternative, a suitable
resistor can be connected in series.
If one of the printer’s internal voltages '+5 VDC EXT' or '+24 VDC
EXT' is used, an external fuse e.g. 0.5 AF, should be additionally
installed to protect the printer electronics.
In the event of an inductive load, an antiparallel connected diode, for
instance, must be used to discharge the induction energy.
In order to minimize the influence of leakage currents at control
outputs, a resistor must, depending on what is connected, be installed
in parallel with the load.
In order to avoid any damages to the printing system, the max. output
currents must not be exceeded or outputs shorted.
Example 3
Precautions
Содержание Dynacode II IP107
Страница 1: ...DYNACODE II IP Ingress Protection Version Operating Manual...
Страница 6: ...Table of Contents Dynacode II IP 6 Operating Manual 03 21...
Страница 10: ...Introduction Dynacode II IP 10 Operating Manual 03 21...
Страница 16: ...Intermittent Mode Dynacode II IP 16 Operating Manual 03 21...
Страница 20: ...Operating Conditions Dynacode II IP 20 Operating Manual 03 21...
Страница 46: ...Load Transfer Ribbon Cassette Dynacode II IP 46 Operating Manual 03 21...
Страница 124: ...Touch Screen Display Dynacode II IP 124 Operating Manual 03 21...
Страница 132: ...Maintenance and Cleaning Dynacode II IP 132 Operating Manual 03 21...
Страница 138: ...Signal Diagrams Dynacode II IP 138 Operating Manual 03 21...
Страница 160: ...Additional Information Dynacode II IP 160 Operating Manual 03 21...
Страница 162: ...Environmentally Friendly Disposal Dynacode II IP 162 Operating Manual 03 21...
Страница 167: ......