![Carl Valentin Dynacode II IP107 Скачать руководство пользователя страница 146](http://html1.mh-extra.com/html/carl-valentin/dynacode-ii-ip107/dynacode-ii-ip107_operating-manual_2558367146.webp)
Error Correction
Dynacode II IP
146
Operating Manual
03.21
Error message
Cause
Remedy
110 Housing open
When starting the print order
the housing cover is not closed.
Close the housing cover and
start the print order anew.
111 EAN.UCC code
Transferred EAN.UCC code is
invalid.
Verify bar code data (see
corresponding specification).
112 Print carriage
Printing carriage does not
move.
Check gear belt (possibly
broken).
113 Applicator error
Option applicator
Error while using applicator.
Check applicator.
114 Left position
Option applicator
Left final position switch is not
in correct position.
Check LEFT final position
switch for correct function and
position.
Check function of pneumatics
for cross traverse.
115 Right position
Option applicator
Right final position switch is not
in correct position.
Check RIGHT final position
switch for correct function and
position.
Check function of pneumatics
for cross traverse.
116 Print position
Option applicator:
The applicator is not in the print
position when trying to print a
label.
Check TOP and RIGHT final
position switch for correct
function and position.
Check pneumatics for function
117 XML parameter
The parameters in the XML file
are not correct.
Please contact your
responsible distributor.
118 Invalid variable
Transferred variable is invalid
with customized entry.
Select correct variable without
customized entry and transfer
it.
119 No ribbon
During the print order the
ribbon roll becomes empty.
Defect at the transfer ribbon
photocell.
Change transfer ribbon.
Check transfer ribbon photocell
(service functions).
120 Wrong directory
Invalid target directory when
copying.
Target directory must not be
within the source directory.
Check target directory.
121 No label PH2
No label found at the rear
printhead (DuoPrint).
Soiled label photocell.
Labels not inserted correctly.
Insert new label roll.
Clean the label photocell.
Check if labels are inserted
correctly.
122 IP occupied
The IP address was already
assigned.
Assign a new IP address.
Содержание Dynacode II IP107
Страница 1: ...DYNACODE II IP Ingress Protection Version Operating Manual...
Страница 6: ...Table of Contents Dynacode II IP 6 Operating Manual 03 21...
Страница 10: ...Introduction Dynacode II IP 10 Operating Manual 03 21...
Страница 16: ...Intermittent Mode Dynacode II IP 16 Operating Manual 03 21...
Страница 20: ...Operating Conditions Dynacode II IP 20 Operating Manual 03 21...
Страница 46: ...Load Transfer Ribbon Cassette Dynacode II IP 46 Operating Manual 03 21...
Страница 124: ...Touch Screen Display Dynacode II IP 124 Operating Manual 03 21...
Страница 132: ...Maintenance and Cleaning Dynacode II IP 132 Operating Manual 03 21...
Страница 138: ...Signal Diagrams Dynacode II IP 138 Operating Manual 03 21...
Страница 160: ...Additional Information Dynacode II IP 160 Operating Manual 03 21...
Страница 162: ...Environmentally Friendly Disposal Dynacode II IP 162 Operating Manual 03 21...
Страница 167: ......