Carinci ECO 25 Скачать руководство пользователя страница 5

5

SAFETY

SAFETY

1.  Do not use the appliance as an incinerator or in any other way other than that in which it was con-

ceived; 

2.  Do not use fuels other than those recommended;

3.  Do not use fl ammable liquids for ignition;

4.  The equipment in operation reaches high temperatures, therefore it is necessary to operate with great 

caution in order to avoid burns;

5. The Boiler 

ECO

, once positioned, must have a radius of 

free space suitable

 (as indicated in pa-

ragraph 2) to ensure easy inspection and maintenance;

6.  Do not make any unauthorized modifi cation on the equipment;

7.  In case of failure or malfunction, use only original spare parts. In any case, the replacement must be 

carried out exclusively by personnel authorized by 

Carinci Group SpA;

8.  In the event of a fi re on the appliance or on the fl ue gas evacuation system, immediately turn off the 

power supply, equip yourself with the appropriate fi re extinguishing systems and promptly request 
the intervention of the fi refi ghters;

9.  Should maintenance or repairs be carried out, make sure that the equipment is not connected to the 

electrical network;

10. Contact with the equipment is prohibited in the presence of wet or damp parts of the body;

11. We recommend positioning the power cable so that it does not come into contact with the hot parts 

of the equipment. In addition, make sure that the power plug is always accessible.

12. It is forbidden to modify the safety devices or the operating parameters on the equipment;

13. Do not reduce or obstruct the ventilation openings necessary for correct combustion in the room whe-

re the equipment is located;

14. Following a long period of non-use, check for any obstructions in the fl ue gas duct and in the ventila-

tion duct before proceeding to start the appliance again;

15. During normal operation of the appliance, the doors must remain closed;

16. The equipment has been designed to operate in any climatic condition but, in the event of particularly 

adverse conditions (e.g. strong wind), safety systems may shut down the equipment. In this case, 
contact the technical assistance service without disabling the safety devices on your own;

17. While loading the pellet tank, avoid contact between the bag and the hot metal parts of the applian-

ce.

Содержание ECO 25

Страница 1: ......

Страница 2: ......

Страница 3: ...uit systems pag 15 4 4 Electronic safety devices pag 16 4 5 Adjustment on the heating circuit pag 16 4 6 Domestic hot water pag 16 5 0 Pellet loading pag 16 6 0 Ignition of the appliance pag 17 7 0 El...

Страница 4: ...liability of the manufacturer for damages caused to people animals or things from installation adjustment maintenance errors and improper use is excluded The installation must be performed by enabled...

Страница 5: ...out make sure that the equipment is not connected to the electrical network 10 Contact with the equipment is prohibited in the presence of wet or damp parts of the body 11 We recommend positioning the...

Страница 6: ...to 25 27 kW ECO 30 with power modulation from 8 95 to 27 62 kW ECO 30 MAX with power modulation from 8 95 to 27 62 kW ECO 30 COMPACT with power modulation from 8 95 to 27 62 kW ECO 30 COMPACT MAX wit...

Страница 7: ...1402 1280 611 690 844 ECO ECO COMPACT 690 1402 1485 844 1360 1485 1031 5 1077 704 1402 ECO equipped with automatic pellet loading ECO equipped with ash compactor Measures expressed in millimeters Not...

Страница 8: ...3 mg Nm 3 mg Nm 3 mg Nm 131 85 128 24 124 64 NOx at 10 02 13 37 13 01 12 65 OGC at 10 02 2 90 2 83 2 76 Dust at 10 02 159 47 156 07 152 67 Weight ECO COMPACT kg 395 Pellet tank Lt 115 395 115 115 Wate...

Страница 9: ...ropriate measures Also check that the walls of the room are reproof The boiler installation room must be equipped with an adequate air vent as speci ed in the standard UNI EN 303 5 Ensure a pressure d...

Страница 10: ...andards UNI TS 11278 UNI EN 1856 1 and UNI EN 1856 2 UNI EN 1443 UNI EN 1806 UNI 7129 1 2 3 4 UNI 10683 12 3 1 GENERAL REQUIREMENTS FOR FLUE GAS DUCTS reference standard UNI 10683 12 art 6 5 3 The ue...

Страница 11: ...e entire length Maximum 2 direction changes of max 45 Draft as required by the appliance in the absence of indications it must be kept at 12 2 Pa In the case of a wet operation they must be equipped w...

Страница 12: ...ween the roof covering and the lower point of the section for the emission of ue gas into the atmosphere this quota must be outside the re ux area and at an adequate distance from obstacles that preve...

Страница 13: ...the design Hydraulic connection example of the Boiler ECO and ECO COMPACT to the Heating System HIGH TEMPERATURE 50 C 75 C Domestic Hot Water Outlet Thermostatic Mixing Valve Cold Water Inlet HIGH TE...

Страница 14: ...GH TEMPERATURE 50 C 75 C 40 20 60 80 100 0 120 C 40 20 60 80 100 0 120 C HEATING DELIVERY RETURN HEATING S 2 NTC 10 K STORAGE TANK ACCUMULATOR TERMOBOILER 800 lt 1 2 30 34 35 29 TERMINAL BOARD CONTROL...

Страница 15: ...r declines all responsibility for damage to things people and or animals caused by the system 4 3 REQUIREMENTS FOR CLOSED CIRCUIT SYSTEMS According to the norm UNI 10412 2 2009 in force in Italy close...

Страница 16: ...OT WATER where applicable The versions with the production of domestic hot water are equipped with a very high ef ciency nned copper heat exchan ger They also have a ow switch which when hot sanitary...

Страница 17: ...proceed in safety Furthermore the Carinci technician must receive the Declaration of System Compliance issued by the installer and also Photographic copy of the chimney plate label User manual or boo...

Страница 18: ...n the Views Menu EXIT Exit function from a Menu or Submenu P1 MENU To enter a Menu or in the Submenus P3 EDIT Enter into edit mode in the Menus SET Saving data in Menu RESET CLEANING FUNCTION Timer re...

Страница 19: ...ic Manual Combustion Combustion formulas Combined Operation Mode Summer Winter Operating status of the system Error code occurred Thermostat value Boiler Temperature read by the boiler probe Operating...

Страница 20: ...ed Menu item can be highlighted Press the P3 key to enter the highlighted submenu obtaining the list of submenus or the setting of the selected parameter in this case Combustion Power Potenza Combusti...

Страница 21: ...enu to change the working time or the auger speed There are 10 steps available 5 to increase and 5 to decrease The 0 value corresponds to the value set in the laboratory The calibration has an effect...

Страница 22: ...om Chrono it is necessary to select the desired mode from the Chrono Mode submenu Choose the type of programming you are interested in setting Daily select the day of the week you want to program 3 on...

Страница 23: ...Flue gas Fan output is also activated to close the Pressure Switch contact thus feeding the Auger 8 6 DATE AND TIME MENU Menu that allows you to set the current time and date Press P4 and P6 keys to...

Страница 24: ...be consi dered Check that the probes are not open reading of the minimum value of the temperature scale or in short circuit reading of the maximum value of the temperature scale 5 Service Message indi...

Страница 25: ...contact the Carinci Group S p A technical service for the appointment of specialized personnel to perform the requested intervention ATTENTION Before carrying out any type of intervention make sure th...

Страница 26: ...s Once cleaned pull out the handle and close the boiler door ATTENTION The cleaning of the heat exchangers must be carried out at least once a year by a quali ed technician T A C Carinci who will carr...

Страница 27: ...the opening Release the catches 5 and empty the contents of the drawer into a special container To put back the drawer perform the procedure in reverse Cleaning the ash collection compartment of the h...

Страница 28: ...r At the end perform the operations above in reverse to restore the initial conditions of the equipment ATTENTION On the ECO COMPACT Boiler if the TEE for the condensate collection inside the Boiler h...

Страница 29: ...on of the gases produced by combustion Chimney pot Element placed on the top of the chimney to protect against adverse weather conditions Condensate Passage from the gaseous state to the liquid state...

Страница 30: ...eable by Carinci Group SpA including power surges lightning proximity to high voltage pylons or other devices in the environment where the equipment is placed which cause magnetic elds i Damages cause...

Страница 31: ...l forfeit the right of warranty of the equipment with all consequences of law also referred to the civil liability towards third parties I am also aware that the right of warranty will lapse even if t...

Страница 32: ...defects or malfunctions on the electrical electronic and mechanical components due to force majeure not foreseeable by Carinci Group SpA including power surges lightning proximity to high voltage pylo...

Страница 33: ...33 33 33...

Страница 34: ...34 34 34...

Страница 35: ...2019 Carinci Group S p A Design Cristian Carinci Copyright all rights reserved even partial reproduction prohibited Edition II Maggio 2019 35...

Страница 36: ......

Отзывы: