background image

18     

RVG 142, RVG 5200 and RVG 6200 Safety, Regulatory User Guide (SM847) 

Ed06 

Minimum Computer System Requirements 

The computer and the peripheral equipment must conform to the IEC 60950 standard. 

Item 

Display and Acquisition 

CPU 

2 GHz Intel Duo Core 

RAM 

2 GB 

Hard disk drive 

1.2 GB for software installation 

80 GB free space to use the software 

Graphic board 

Nvidia/ATI based board with 256 MB of RAM 

Display 

1024 x 768 minimum screen resolution 

32 bits color mode 

Operating system 

 Windows 10 (64 bits)

USB 2.0 

2 ports available 

Ethernet 

100 BaseT 

CD/DVD drive 

DVD-ROM drive is required to install the product. 

Backup media 

Removable/portable, external hard disk drive. 

Imaging Performance Information 

Imaging performance of RVG 142, RVG 5200 and RVG 6200 complies with the IEC 61223-3-4: 

2000 standard. 

Controlling the Image Quality 

For optimum results, perform a control test of the image quality. To do this, see the 

User & 

Installation Guide

Содержание RVG 142

Страница 1: ...Safety Regulatory and Technical Specifications User Guide RVG 142 RVG 5200 RVG 6200...

Страница 2: ...formation contained in this guide may be subject to modification without notice justification or notification to the persons concerned No part of this guide may be reproduced without the express permi...

Страница 3: ...7 Marking and Labeling Symbols 8 Label Locations 9 2 Regulatory Information 10 General Regulatory Information 10 Compliance With International Regulations 14 3 Technical Specification 15 Factory 15 M...

Страница 4: ...puter using a USB cable To do so they require additional components such as conventional extra oral X ray source and imaging software In addition RVG 6200 can be used with an RVG Connect unit connecte...

Страница 5: ...anesthetics or flammable agents It is not recommended to use accessories other than those specified in this document and sold by Carestream Dental Single use disposable protective hygienic sleeves mus...

Страница 6: ...g wipes or soak it in a disinfecting solution with intermediate level hospital disinfectant with label claims of tuberculocidal activity for example a chlorine containing product a quaternary ammonium...

Страница 7: ...To disinfect the arm and ring follow these steps 1 Disassemble the metal arm and the plastic ring 2 Remove any residue from components with hot water and soap 3 Put components in disinfection pouches...

Страница 8: ...n the European Union this symbol indicates Do NOT discard this product in a trash receptacle use an appropriate recovery and recycling facility Contact your local sales representative for additional i...

Страница 9: ...cations of RVG 5200 RVG 6200 and RVG Connect Figure 1 RVG 142 RVG 5200 RVG 6200 sensor box label Figure 2 RVG 142 RVG 5200 and RVG 6200 USB cable label Figure 3 RVG 142 product label Figure 4 RVG Conn...

Страница 10: ...ral Standard Usability EN 62366 IEC 62366 Medical devices Application of usability engineering to medical devices EN ISO 14971 Medical devices Application of risk management to medical devices EN ISO...

Страница 11: ...ing to the EMC information provided in this document Communication Equipment Portable and mobile Radio Frequency RF communications equipment can affect the Electromagnetic Compatibility of RVG 142 RVG...

Страница 12: ...e Electromagnetic Environment Guidance RF emissions CISPR 11 Group 1 RVG 142 RVG 5200 and RVG 6200 use RF energy only for their internal function Therefore their RF emissions are very low and are not...

Страница 13: ...IEC 61000 4 2 8 kV contact 15 kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 Electrical fast transient...

Страница 14: ...tations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagn...

Страница 15: ...and RVG 6200 Safety Regulatory User Guide SM847 Ed06 15 3 Technical Specification Factory TROPHY 4 rue F Pelloutier Croissy Beaubourg 77435 Marne la Vall e Cedex 2 France Manufacturer Model RVG 5200...

Страница 16: ...Size 1 1168 x 1562 pixels Size 2 1402 x 1874 pixels Sensor active surface dimensions Size 1 22 2 x 29 6 mm Size 2 26 6 x 35 5 mm Gray scale 4096 grey levels 12 bits Dimension Size 1 27 6 mm W x 37 7 m...

Страница 17: ...echnical Specification Components Specification RVG Connect Ethernet interface 100 BaseT USB connector Receptacle Type A USB Interface USB 2 0 high Speed Power supply interface Power Over Ethernet POE...

Страница 18: ...based board with 256 MB of RAM Display 1024 x 768 minimum screen resolution 32 bits color mode Operating system Windows 10 64 bits USB 2 0 2 ports available Ethernet 100 BaseT CD DVD drive DVD ROM dr...

Страница 19: ...ing Conditions Temperatures 10 40 C Relative humidity 30 85 Atmospheric pressure 700 1060 hpa Altitude Up to 3000 m Storage Conditions Temperatures 10 60 C Relative humidity 10 90 Atmospheric pressure...

Страница 20: ...urg 77435 Marne la Vall e Cedex 2 France Authorized Representatives Authorized Representative in the European Community Authorized Representative in Brazil CARESTREAM DENTAL BRASIL EIRELI Rua Romualdo...

Страница 21: ...e Guide de s curit de r glementation et de sp cifications techniques destin l utilisateu Manuale per l utente di specifiche tecniche normative e di sicu ezza Gua del usuario de las especificaciones tc...