DQG/('GLVSOD\
Fig. 2.3.1 shows the front panel of the plug-in: display and buttons. On the front
panel of the instrument there is a three-digit display (ref. 4 in the figure 2.3.1), and
three LEDs back-lighting the buttons (refs. 1, 2 and 3 in Fig. 2.3.1).
These indicate:
this LED indicates the
VWDWXV RQ RU RII of the actuator controlled, (normally a
compressor); the button is back-lit by a green LED and is available only on the
7RS models.
The status of the LED can be the following, to indicate:
DOZD\VRQ
&2035(6625,123(5$7,21
FRQWLQXRXVIODVKLQJ
request pending for compressor activation
IODVKLQJZLWKF\FOHVDQGDSDXVH
continuous cycle on
7DE
ó
$ODUPVLJQDOpresent only on the 7RS models, the button is back-lit by a red LED.
ì
'HIURVWLQSURJUHVV present only on the 7RS models, the button is back-lit by a green LED. The status of the LED can be:
DOZD\VRQ
defrost in progress
FRQWLQXRXVIODVKLQJ
request pending for defrost
7DE
ö
THE LED DISPLAY 6+2:621(2)7+()2//2:,1*3,(&(62),1)250$7,21$&&25',1*727+(
)81&7,21,1352*5(66
•
in normal operation: value measured by the ambient probe or the second probe;
•
when setting parameters: code of the parameter or the associated value;
•
during an alarm event: flashing code of the alarm detected, alternating with the temperature value.
The temperature measured by the probe is displayed with resolution to a degree (ºC or ºF).
The display range for the temperature is: -50 ÷ 90 ºC (or -50 ÷ 127 ºF).
For the parameters, the values can vary from -99 to +199 and in some cases from -127 to +127. The unused segments of the left-
most digit are normally always off; expansion modules (Serial 485 and HACCP) can be used to signal states or parameter
programming modes. For a complete description please refer to the expansion module manual.
8VLQJWKHNH\SDG
Three buttons (5, 6 and 7 in Fig.2.3.1) are used to perform the activation and deactivation of the instrument’s operating states and
set the parameters.
The use of the buttons can be divided into two different situations: one in of normal operation, and the other to modify the
parameters. For each button, the following are the possible actions associated with both possibilities.
In
QRUPDORSHUDWLRQ and if pressed for more than 5 seconds:
•
activates/deactivates continuous cycle (compressor).
In
PRGLI\SDUDPHWHUmode:
•
moves from one parameter to the next;
•
increases the value of the parameter.
,QQRUPDORSHUDWLRQ:
•
silences the audible alarm (only if featured);
•
displays and/or sets the
6HW3RLQW;
•
if pressed for more than 5 seconds not during an alarm: accesses the menu for setting type ‘F’ parameters
(frequent);
•
if pressed when turning on the instrument, together with the
button, activates the parameter RESET
procedure.
In
PRGLI\SDUDPHWHUmode:
•
displays the value of the selected parameter /exits the display;
•
if pressed for more than 5 seconds in modify parameter mode, saves the changes.
In
QRUPDORSHUDWLRQ:
•
if pressed for more than 5 seconds: starts a manual defrost, if enabled.
In
PRGLI\SDUDPHWHUmode:
•
moves from one parameter to the previous;
•
decreases the value of the parameter.
÷
ø
ú
ö
ú
ó
ø
ì
÷
)LJ