CareFusion LE100 CE Скачать руководство пользователя страница 10

 

file: n:\article\cos14310m5-v1_07car-en\20140117_cos14310m5-v1.07car-en_handbuch_carefusion_laufband-ergometer_print.doc 

© 2014 h/p/cosmos sports & medical gmbh     [email protected]     created 17.01.2014     printed 07.05.2014     page: 10 of 16 

 

11.4

 

Treadmill ergometer, 200/75 up to 300/125 (LE580 up to LE720) 

LE650 CE 

LE580 CE

 

LE590 CE

 

LE600 CE

 

LE650 CE

 

LE680 CE

 

LE680 CE

 

LE700 CE

 

LE720 CE

 

UserTerminal  
(display & keyboard) 

External control unit with TouchScreen 

Power supply AC 
(standard, read nameplate), 
dedicated line required. 

200 V 3N~ / 208 V 3N~ / 400 V 3N~

with N and PE 

(peak performances for milliseconds; max. 1s/min during heel strike) 

Fuse (standard, read nameplate) 

3 x C 32 A at 400 V 3N~

Power input (long time) 

7500 VA

Power input (momentary) 

15200 VA

Drive motor capacity 

11000 VA

Elevation motor capacity 

370 VA

Safety standards 

MDD, directive 93/42/EEC + 2007/47/EC, 

IEC EN 60601-1 (VDE 0750), IEC EN 60601-1-2, IEC EN 60601-1-4 

VDE 0751, EN 957-1, EN 957-6, Machinery Directive 2006/42/EC 

Leakage current 

0.25 mA

Isolation transformer 

3 x 3000 VA

Degree of protection: 

class I 

M

 / type B 

R

 / IP 20 

Overvoltage category 

Category III: Life-Earth < 300 Volt = transient over-voltage limit 4000 Volt 

Mode of operation  

continuous operation with intermittent loading (according to IEC 60601-1) 

Field of application / accuracy 

sports and medical / S,I,A (EN957)

[r] = suitable for bicycle and wheelchair application (from running surface 3000 x 1250 mm standard) 

Classification according to MDD 

active therapeutic device and active diagnostic device, risk class II b 

Speed 
Definition 

0.0 ... 40.0 km/h / 0.1 km/h

0.0 ... 11.11 m/s / 0.1 m/s 

Speed accuracy* 

+/- 5 % (class A based on EN 957)

Option special speed 

0.0 ... 50.0 or ... 60.0 or ... 80.0 km/h

on request higher speed versions than 40 km/h only for sports models 

Angle of inclination** 
Definition 

-35.0 % ... +35.0 %

0.1 % 

-27.0 % ... +27.0%** 

0.1 % 

Содержание LE100 CE

Страница 1: ...tachement only Foreword chapter 1 model overview chapter 11 technical data chapter 12 options and accessories chapter 17 contact treadmill ergometer LE100 CE LE200 CE LE250 CE LE300 CE LE500 CE LE580...

Страница 2: ...e cos14310m5 v1_07car en 20140117_cos14310m5 v1 07car en_handbuch_carefusion_laufband ergometer_print doc 2014 h p cosmos sports medical gmbh email h p cosmos com created 17 01 2014 printed 07 05 2014...

Страница 3: ...nly The customer user should perform this maintenance and monitoring work Some safety checks or monitoring for example harnesses and ropes running belt condition and position etc have to be performed...

Страница 4: ...e cos14310m5 v1_07car en 20140117_cos14310m5 v1 07car en_handbuch_carefusion_laufband ergometer_print doc 2014 h p cosmos sports medical gmbh email h p cosmos com created 17 01 2014 printed 07 05 2014...

Страница 5: ...c 2014 h p cosmos sports medical gmbh email h p cosmos com created 17 01 2014 printed 07 05 2014 page 5 of 16 1 Model overview n medical running machines c sports fitness running machines LE100 CE LE2...

Страница 6: ...seconds max 1s min during heel strike Drive motor capacity 3300 VA Elevation motor capacity n a 390 VA Safety standards n MDD directive 93 42 EEC 2007 47 EC IEC EN 60601 1 VDE 0750 VDE 0751 IEC EN 606...

Страница 7: ...ystem manual Number of stored programmes 6 training profiles 10 test profiles 8 user definable profiles RS232 Digital interface serial port USB converter optional COM1 standard COM2 optional COM3 opti...

Страница 8: ...Drive motor capacity 3300 VA Elevation motor capacity n a 500 VA Safety standards n MDD directive 93 42 EEC 2007 47 EC IEC EN 60601 1 VDE 0750 VDE 0751 IEC EN 60601 1 2 IEC EN 60601 1 4 EN 957 1 EN 95...

Страница 9: ...cted Central lubrication system manual Number of stored programmes 6 training profiles 10 test profiles 8 user definable profiles RS232 Digital interface serial port USB converter optional COM1 standa...

Страница 10: ...standards n MDD directive 93 42 EEC 2007 47 EC IEC EN 60601 1 VDE 0750 IEC EN 60601 1 2 IEC EN 60601 1 4 VDE 0751 EN 957 1 EN 957 6 Machinery Directive 2006 42 EC Leakage current 0 25 mA Isolation tr...

Страница 11: ...nductivity caused by condensation is to be expected Central lubrication system manual running machines with r have automatic central lubrication system Number of stored programmes 6 training profiles...

Страница 12: ...7 stop button for hand grip in the arm support right hand side Additional stop button left cos10108 stop button for hand grip in the arm support left hand side h p cosmos additional keyboard cos100680...

Страница 13: ...109 for running machines with user terminal free with safety arch additional keyboard extra safety stop Magnet with ripcord incl plastic clip spare part cos101699 safety stop lanyard pull cord with ma...

Страница 14: ...male female USB Adapter optionally available cos12769 01 Connection cable RS232 15 m cos11889 RS232 15 m Sub D 9 pin male female USB Adapter optionally available cos12769 01 Potential equalization cab...

Страница 15: ...orresponding phone fax or email for qualified help Sales service carefusion GmbH Leibnizstrasse 7 DE 97204 Hoechberg Wuerzburg Germany Sales department Service department phone 49 9 31 49 72 280 phone...

Страница 16: ...cos14310m5 v1_07car en 20140117_cos14310m5 v1 07car en_handbuch_carefusion_laufband ergometer_print doc 2014 h p cosmos sports medical gmbh email h p cosmos com created 17 01 2014 printed 07 05 2014...

Отзывы: