background image

T

RAVEL

'

D

IRECT 

R

ESPONSE

 

I

NSTALLATION 

M

ANUAL

 

C

AREFREE OF 

C

OLORADO

 

052567-001r5 

W

IRING AN 

A

DDITIONAL 

E

XTEND

/R

ETRACT 

S

WITCH

 

This section is for wiring an additional E

XTEND

/R

ETRACT

 switch. 

The switch must be momentary on, single 

pole, double throw, center OFF 
(Momentary ON – OFF – Momentary ON). 

1. 

Route wires for the second switch to the 
main switch location.  Wires should be a 
minimum 18awg. 

2.  Splice the wires in parallel with the 

E

XTEND

/R

ETRACT 

switch wires from the 

switch cable.  Pin 1 of the additional 
switch should go to pin 1 of the main 
patio switch etc. 

 

 

A

TTACH THE 

L

ABEL

 

After completing and testing the system, attach the Direct Response identification label to the bottom of the 
motor arm. 

1.  Thoroughly clean and dry the area at the bottom of the RH (motor) arm. 

2.  Remove the release paper and attach the "DR" label in the area shown 

between the Carefree logo and the top of the plate.  

Gray

Yellow

Brown

On/Off

Extend/Retract

Switch Cable

Rear View of

Switch Assy

LCDR003b

Gray

Yellow

Brown

Additional

Extend/Retract

Switch 

LCDR006

Place DR Label
In This Area 

Содержание DIRECT RESPONSE

Страница 1: ...stallation TABLE OF CONTENTS Prior to Installing the Kit 3 Installing the Sensor 4 Switch Installation 7 Wiring an Additional Extend Retract Switch 8 Attach the Label 8 Read this manual before installing or using this product Failure to follow the instructions and safety precautions in this manual can result in personal injury and or cause the product to not operate properly Carefree of Colorado 2...

Страница 2: ...al personal injury hazards Obey all safety messages that follow this symbol to avoid possible personal injury or death WARNING Indicates a hazardous situation which if not avoided could result in death or serious bodily injury CAUTION Indicates a hazardous situation which if not avoided may result in minor or moderate bodily injury NOTICE Indicates a situation that may result in equipment related ...

Страница 3: ... exterior wall as described in the awning installation instructions These instructions replace the switch and wiring directions included with the awning For Existing Installations The installer must locate and remove any existing switches Access to the motor cable and the 12VDC Ground wires is required 1 Determine the location of the switches 1 1 Do not mount the switches near heat producing eleme...

Страница 4: ...6 Detach the motor assembly from the arm 7 For units that had the emergency terminals on the rear cover refer to Detail C for units without the emergency terminals go to step 8 7 1 Partially pull the motor cable from the rear of the arm approximately 9 10 7 2 Cut the cable approximately 7 from the top of the channel Remove but DO NOT discard the cable that was cut 7 3 On the cable remaining in the...

Страница 5: ...nnel Press New Cable into Open Groove of Channel 2 Clean this surface Cutoff Tab from Bottom of Front Cover DETAIL A 12V Direct Response Control Module 060686 001 Rev 1 0 DETAIL C DETAIL D DETAIL E To Switch DETAIL F Front Channel Channel 2 Alternate Switch Routing LCDR001a Double Sided Tape Switch Cable 3 5 DETAIL B Cord Retainer Motor Patch Cable Route long red black module wires inside arm to m...

Страница 6: ...wiring diagram is on page 7 17 In the front channel attach the red and black wires from the module to the motor cable inside the channel 18 Secure the red and black wires into the groove of the front channel using a 2 piece of cord retainer 19 Attach the rear cover 20 Detail D Cut or break off the tab on the bottom of the front cover Attach the front cover 21 Detail E Route the new cable down the ...

Страница 7: ...erminal of the ON OFF switch 5 Terminate the BLACK wire from the motor cable with a 25 14 16 awg male terminal 6 Run a minimum 14 awg wire to chassis ground Suitable ground would be the vehicle chassis or conductive structure connected to the chassis Terminate the wire with 25 14 16 awg female terminal and connect to the black wire from the cable 7 Run a minimum 14 awg wire from the power distribu...

Страница 8: ...END RETRACT switch wires from the switch cable Pin 1 of the additional switch should go to pin 1 of the main patio switch etc ATTACH THE LABEL After completing and testing the system attach the Direct Response identification label to the bottom of the motor arm 1 Thoroughly clean and dry the area at the bottom of the RH motor arm 2 Remove the release paper and attach the DR label in the area shown...

Отзывы: