background image

T

RAVEL

'

D

IRECT 

R

ESPONSE

 

I

NSTALLATION 

M

ANUAL

 

C

AREFREE OF 

C

OLORADO

 

052567-001r5 

I

NSTALLING THE 

S

ENSOR

 

This section is for fitting the motion sensor and wiring into the motor arm and head. 

1.  Open the awning completely. 

2.  Disconnect power to the awning. 

3. 

(Detail A)

  Remove the front cover.  There are six (6) 

small screws through the back cover.  Set parts aside. 

4.  Examine the rear cover. 

4.1. 

For rear covers with emergency terminals: 

 

Disconnect the wires from the emergency terminals 
(Detail B).  Do not remove the wires from the motor 
at this time. 

4.2. For rear covers without emergency terminals: 

 

Separate the quick connect terminals in the arm. 

4.3.  Remove the rear cover.  Set parts aside. 

4.4. For rear covers with emergency terminals:  Remove 

the emergency terminals from the rear cover and 
discard.  Use care to not damage the rear cover. 

5.  Remove the two (2) screws holding the roller tube in 

the endcap.  Pull the roller tube out of the end cap 
while holding the arm.  Support the roller tube  

 NOTICE

  

Do not allow the roller tube to drop 

toward the ground.  The twisting motion can 
cause serious damage to the idler arm. 

NOTE:  

The arm will extend out slightly when the 

roller tube is detached.

 

6.  Detach the motor assembly from the arm. 

7.  For units that had the emergency terminals on the 

rear cover (refer to Detail C):

 

(for units without the emergency terminals go to step 8)

 

7.1. Partially pull the motor cable from the rear of the 

arm (approximately 9"-10") 

7.2. Cut the cable approximately 7" from the top of 

the channel.  Remove but 

DO NOT

 discard the 

cable that was cut. 

7.3. 

On the cable remaining in the arm:  Strip 
approximately 2" of the outer insulation to expose 
the wires. 

7.4. Strip and terminate the two wires in the cable with 

.24, 14-16awg insulated female spade connectors. 

7.5. Press the cable back into the channel groove leaving the connectors exposed. 

7.6. For the cable that was removed:  From the cut end, strip approximately 5" of the outer insulation to 

expose the wires. 

7.7. Strip and terminate the two wires in the cable with .24, 14-16awg insulated male spade connectors. 

7.8. On the motor, replace the red and black wires with the newly made motor patch cable.  Match the wire 

colors (replace the red wire with the cable's red wire and the black wire with the cable's black wire). 

Motor

Cable

Emergency
Terminals

Emergency

Terminals

RH Motor Head

7"

.25, 14-16awg
Female Spade
Terminals (x2)

Motor
Patch Cable

.25, 14-16awg
Male Spade
Terminals (x2)

5"

DETAIL 

A

Rear

Cover

Motor

Assy

Motor

Cable

Front

Cover

DETAIL 

B

DETAIL 

C

LCDR001b

No

Terminals

Quick

Connects

Roller Tube Endcap

Содержание DIRECT RESPONSE

Страница 1: ...stallation TABLE OF CONTENTS Prior to Installing the Kit 3 Installing the Sensor 4 Switch Installation 7 Wiring an Additional Extend Retract Switch 8 Attach the Label 8 Read this manual before installing or using this product Failure to follow the instructions and safety precautions in this manual can result in personal injury and or cause the product to not operate properly Carefree of Colorado 2...

Страница 2: ...al personal injury hazards Obey all safety messages that follow this symbol to avoid possible personal injury or death WARNING Indicates a hazardous situation which if not avoided could result in death or serious bodily injury CAUTION Indicates a hazardous situation which if not avoided may result in minor or moderate bodily injury NOTICE Indicates a situation that may result in equipment related ...

Страница 3: ... exterior wall as described in the awning installation instructions These instructions replace the switch and wiring directions included with the awning For Existing Installations The installer must locate and remove any existing switches Access to the motor cable and the 12VDC Ground wires is required 1 Determine the location of the switches 1 1 Do not mount the switches near heat producing eleme...

Страница 4: ...6 Detach the motor assembly from the arm 7 For units that had the emergency terminals on the rear cover refer to Detail C for units without the emergency terminals go to step 8 7 1 Partially pull the motor cable from the rear of the arm approximately 9 10 7 2 Cut the cable approximately 7 from the top of the channel Remove but DO NOT discard the cable that was cut 7 3 On the cable remaining in the...

Страница 5: ...nnel Press New Cable into Open Groove of Channel 2 Clean this surface Cutoff Tab from Bottom of Front Cover DETAIL A 12V Direct Response Control Module 060686 001 Rev 1 0 DETAIL C DETAIL D DETAIL E To Switch DETAIL F Front Channel Channel 2 Alternate Switch Routing LCDR001a Double Sided Tape Switch Cable 3 5 DETAIL B Cord Retainer Motor Patch Cable Route long red black module wires inside arm to m...

Страница 6: ...wiring diagram is on page 7 17 In the front channel attach the red and black wires from the module to the motor cable inside the channel 18 Secure the red and black wires into the groove of the front channel using a 2 piece of cord retainer 19 Attach the rear cover 20 Detail D Cut or break off the tab on the bottom of the front cover Attach the front cover 21 Detail E Route the new cable down the ...

Страница 7: ...erminal of the ON OFF switch 5 Terminate the BLACK wire from the motor cable with a 25 14 16 awg male terminal 6 Run a minimum 14 awg wire to chassis ground Suitable ground would be the vehicle chassis or conductive structure connected to the chassis Terminate the wire with 25 14 16 awg female terminal and connect to the black wire from the cable 7 Run a minimum 14 awg wire from the power distribu...

Страница 8: ...END RETRACT switch wires from the switch cable Pin 1 of the additional switch should go to pin 1 of the main patio switch etc ATTACH THE LABEL After completing and testing the system attach the Direct Response identification label to the bottom of the motor arm 1 Thoroughly clean and dry the area at the bottom of the RH motor arm 2 Remove the release paper and attach the DR label in the area shown...

Отзывы: