background image

 

BAUD RATE AND WEIGHT MODE SELECTION 

The AS-400D and AS-410D can be operated in either a pounds/ounces mode or UPS pounds 
only mode. A setup switch makes this selection.  The AS-420D operates only in a pounds 
mode and cannot be set to a pounds/ounces mode of operation.   

 
NOTE!  Although the AS-420D operates in a pounds only mode, it does not use 
the UPS pounds only command set. 

 

 
Switch S1 (2, 3 and 4) are used to select the baud rate for serial communication via the scale 
port.  Switch S1 (1 and 5) are used to select the weight mode.

 

 
To gain access to the switch S1:  

1.  Unplug the scale from the power outlet. 

2.  Remove the stainless steel platform. 

3.  Once the platform has been removed, you will see the switch located on the main 

printed circuit board. 

4.  Using a small screwdriver or similar device, set the five switches to the desired setting 

as indicated in the table. 

5.  Replace the scale platform, and then plug in the power cord.  This will reset and restart 

the scale for normal operation. 

 

FUNCTION

 

SETTING

 

S1-1

 

S1-2

 

S1-3

 

S1-4

 

S1-5

 

Baud Rate

 

19200 

 

OFF OFF OFF 

 

 9600 

 

ON 

OFF 

OFF 

 

 

4800 

  OFF ON OFF   

 2400 

 

ON 

ON 

OFF 

 

 1200 

 

OFF 

OFF 

ON 

 

 

600 

 

ON OFF ON 

 

 300 

 

OFF 

ON 

ON 

 

 

DISABLED 

  ON ON ON   

 

 

 

 

 

 

 

Weight Mode

 

Pounds/Ounces 

OFF 

   

OFF 

 

UPS Pounds Mode 

ON 

 

 

 

ON 

 

 

 

NOTE !  Change switch settings only with power to the scale disconnected!  
If changing between Pounds/Ounces and Pounds only mode, the scale must 
be recalibrated. 

 

 
 

Settings For UPS Online Users 

The AS-400D and AS-410D dip switches must be set as follows to work with UPS OnLine 
software.  Set scale type to Fairbanks 70-2453-4 in the UPS software. 
 

Switch 

 

  

  

  

  

  

Setting 

 ON 

 ON 

 OFF 

 OFF 

 

 ON 

 

• 

9600 Baud 

• 

7 Data Bits 

• 

Odd Parity 

• 

1 Stop Bit 

• 

UPS Pounds Mode 

  

NOTE!  Change switch 
settings only with power 
to scale disconnected!  

Отзывы: