To install the remote alarm, make the following connections:
1. Connect the COMMON terminal on the cabinet switch to the COMMON wire on the alarm.
2a. To get an alarm when the switch contacts open, connect the OPEN ON FAIL terminal on the cabinet to the
OPEN ON FAIL wire on the alarm.
2b. To get an alarm when the switch contacts close, connect the CLOSE ON FAIL terminal on the cabinet to the
CLOSE ON FAIL wire on the alarm. The COMMON and CLOSE ON FAIL wires must be tied together in this application.
3. Plug the alarm system service cord into an electrical outlet.
The contacts will trip in the event of a power outage, high temperature alarm or low temperature alarm.
7.10 Final Checks
Before start up, be sure to complete the following steps:
1. Make sure that the unit is free of all wood or cardboard shipping materials, both inside and outside.
2. Check the positions of the shelves, drawers and baskets. If you want to adjust the positions,
see instructions in
Section 7.4, Section 7.5
and
Section 7.6
.
3. Verify that the unit is connected to a dedicated circuit.