Motor connection
• Connect one of the motor phases to binding post
3
-
F1
; the neutral wire to binding post
4
-
C
; and the second motor phase to binding post
5
-
F2
.
• Connect the
230V
power supply to binding posts
1
and
2
.
• If the motor rotates in the wrong direction, invert the
F1
and
F2
phase wires.
Selector switch connection
• Wire a selector switch or an open close button between binding posts
7
-
8
-
9
and select the required function using dip-switch
D1
as follows:
Function selection dip-switches for binding posts 7, 8 and 9
dip 1
dip 2
T1
T2
Note
OFF
OFF
Open
Close
Default option
ON
OFF Sequential button
Timer
Sequential button = open - stop - close - stop
OFF
ON
Open
Close
Dead man function only during closing
ON
ON
Open
Close
Dead man function during opening and closing
1
2
3
4
ON
Dip D1