Electrical connection (fig. 1)
Before connecting the device to the mains make sure that:
- the voltage and frequency rated on the data plate conform to those of the mains supply;
- an all pole circuit breaker which leaves at least
3 mm
between the contacts has been installed
between the device and the mains;
- the wires are fastened down using a cable clamp.
Attention!
- a
6,3A
fuse (not supplied with the product) must be wired in series with the
230V
power supply.
-
only low voltage circuits may be wired to the external circuit binding posts
7…9
.
2
3
4
5
6
DC0598
1
230V
4
3
2
1
ON
P1
L
N
M
+
C
F1
F2
R1
R2
7
8
9
T1
T2
COM
ANT
D1
6,3A
Collegamento S504T10 per serrande
S504T10
11-12-2019
DC0598
Description:
Product Code :
Date :
Drawing number :
P.J.Heath
CARDIN ELETTRONICA S.p.A
- 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Draft :
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
L1
1
1-2 Power supply
230Vac 50-60Hz
3
Power supply earth connection
4
Motor output (phase 1)
5
Motor output (neutral)
6
Motor output (phase 2)
7
T1
(N.O.) input
8 Common
9
T2
(N.O.) input
L1
Indicator led
P1
Programming button