BARRIERA ALL'INFRAROSSO MODULATO "MINI FTR893C3"

Il presente manuale si rivolge a persone abilitate all'installazione di "APPARECCHI UTILIZZATORI DI 
ENERGIA ELETTRICA" e richiede una buona conoscenza della tecnica, esercitata in forma professionale. 
Prima di dar inizio all’installazione prendere visione dei dispositivi di sicurezza previsti dal prodotto per 
utilizzarli con la massima efficacia.
• Dispositivo classe 3 a doppio relé con scambi in serie, il contatto NC è conferme alle norme della 
categoria 3 della 

UNI EN ISO 13849-1

 (aggiornamento della  

EN954-1

).

Attenzione!

 Solo per clienti dell’EU - 

Marcatura WEEE

.

Il simbolo indica che il prodotto alla fine della propria vita utile deve essere raccolto 
separatamente dagli altri rifiuti. L’utente dovrà pertanto conferire l’apparecchiatura agli 
idonei centri di raccolta differenziata dei rifiuti elettronici ed elettrici, oppure riconsegnarla 
al rivenditore al momento dell’acquisto di una nuova apparecchiatura di tipo equivalente, 
in ragione di uno a uno. L’adeguata raccolta differenziata per l’avvio al riciclaggio, al 

trattamento e allo smaltimento ambientalmente compatibile contribuisce ad evitare possibili effetti 
negativi sull’ambiente e sulla salute e favorisce il riciclo dei materiali. Lo smaltimento abusivo del 
prodotto da parte del detentore comporta l’applicazione delle sanzioni amministrative previste dalla 
normativa vigente nello Stato Comunitario di appartenenza.

La barriera all'infrarosso modulato "FTR893C3" è composta da:

1)  Una centralina di controllo FTR893C3
2)  Un'ottica TX con cavo schermato NERO e supporto per fissaggio a pannello.
3)  Un'ottica RX con cavo schermato  GRIGIO e supporto per fissaggio a pannello.

Versione 

Lunghezza cavo TX (Nero) 

Lunghezza cavo RX (grigio)

FTR893C3 

4 m

 

4 m

Possibilità di impiego

La barriera a raggio infrarosso modulato "

FTR893C3

" rappresenta un efficiente sistema di sicurezza 

per la protezione di passaggi o spazi soggetti ad installazioni automatizzate di ascensori. Il sistema è 
adatto per applicazione su passaggi di luce compresa fra 

0,5 

2,5

 

metri

 all'interno di edifici. 

L'uso e l'installazione di questa apparecchiatura deve rispettare rigorosamente le indicazioni fornite 
dal costruttore e le normative di sicurezza vigenti.

INSTALLAZIONE (fig.1-4) 

Attenzione!

 Se si installano più 

FTR893C3

 è opportuno, al fine di un corretto funzionamento, 

che i coni di emissione delle singole ottiche non si sovrappongano. I due raggi devono essere 
distanti circa 

1,5 metri

 uno dall'altro. 

1)  Le ottiche vengono fornite complete di cavi che 

non è possibile allungare

. Se invece si desidera 

accorciarli è preferibile intervenire sul cavo RX cosicchè l'ottica RX risulti più vicina alla logica di 
controllo ricevendo così un segnale più pulito.

 

N.B.:

 evitare di spellare il cavo schermato per più di 

2 cm

 nella connessione alla morsettiera di 

controllo (questo accorgimento diminuisce la sensibilità ai disturbi esterni).

2)  Verificare attentamente che le superfici sulle quali si devono fissare i supporti in plastica (

fig. 3a

)

 

siano in bolla e perfettamente affacciate fra loro in quanto non è consentita una regolazione esterna.

3)  Determinare il punto in cui andrà collocata la logica di controllo tenendo conto della lunghezza 

delle ottiche a disposizione; se l'installazione avviene all'esterno dell'edificio la logica di controllo 
deve essere inserita in contenitore stagno (

IP55

).

4)  Prevedere il passaggio dei cavi di collegamento dalla logica di controllo al punto di fissaggio delle 

ottiche (

fig. 3b

) evitando il collocamento in canalette in cui vi siano cavi ad alta tensione.

5)  Calcolare le altezze (

"H" fig. 2

) rispetto al suolo e marcare i punti di fissaggio dei supporti in plastica.

6)  Utilizzando un trapano con punta da 

Ø12

 effettuare i fori sui punti marcati (

fig. 3

).

7)  Inserire i supporti in plastica (

fig. 3a

)

8)  Fissare le ottiche al supporto infilando il cavo ed esercitando una pressione (

fig. 3b

). Una volta 

bloccate, le ottiche non possono essere estratte dall'esterno (garanzia contro la manomissione). 

9)  Qualora sia necessario sostituire l'ottica, scollegare il cavo di collegamento ed esercitare una 

pressione dall'interno verso l'esterno per liberare l'ottica dal suo supporto in plastica.

10)  Effettuare i collegamenti rispettando rigorosamente lo schema riportato in 

fig. 4

. La sezione minima 

del cavo di alimentazione deve essere di 

0,2 mm

2

 (

AWG#24

).

11) Selezionare la tipologia del contatto in uscita: 

NC/8.2 kΩ

.

12)  Selezionare la portata come indicato 

nella tabella a pagina 4

 ricordando che i dati relativi alla portata 

si riferiscono ad una installazione ottimale che rispetta tutti i punti del paragrafo "Installazione".

Anomalie di funzionamento

•  Il led verde è spento;
  -   verificare il collegamento elettrico;
  -   verificare il valore e polarità della tensione di alimentazione (

12/24 Vac/dc

).

•  Il led rosso rimane sempre acceso:
  -  verificare che le ottiche siano correttamente allineate;
  -   verificare che il raggio non sia ostacolato;
  -   verificare l'integrità delle ottiche;
  -   verificare l'integrità dei cavi.

MODULATED INFRARED BARRIER "MINI" FTR893C3

These instructions are aimed at professionally qualified "installers of electrical equipment" and must 
respect the local standards and regulations in force. Before commencing with the installation of this 
appliance familiarise yourself with the safety devices required by the system, only then will you be 
able to use them to great effect. 
This class 3 equipment has a double relay with serial exchange. The NC contact conforms to 

category 

3 of the directive 

UNI EN ISO 13849-1

 (update of the 

EN954-1

).

Attention!

 Only for EU customers - 

WEEE marking

.

This symbol indicates that once the products life-span has expired it must be disposed 
of separately from other rubbish.
The user is therefore obliged to either take the product to a suitable differential collec-
tion site for electronic and electrical goods or to send it back to the manufacturer if the 
intention is to replace it with a new equivalent version of the same product. Suitable 

differential collection, environmental friendly treatment and disposal contributes to avoiding negative 
effects on the ambient and consequently health as well as favouring the recycling of materials. Illicitly 
disposing of this product by the owner is punishable by law and will be dealt with according to the laws 
and standards of the individual member nation. 

The modulated infrared barrier "FTR893C3" is composed of:

1)  A FTR893C3 control box
2)  One transmitter sensor with a "BLACK" shielded cable and wall mounting support.
3)  One transmitter sensor with a "GREY" shielded cable and wall mounting support.

Version 

Cable length TX (Black) 

Cable length RX (Grey)

FTR893C3 

4 m

 

4 m

Use

The modulated infrared barrier "

FTR893C3

" constitutes an efficient control and safety system for 

the protection of automatic installations such as lifts and is suitable for controlling passageways of 
from 

0,5

 to 

2,5

 

meters

 inside buildings.

The use and installation of these appliances must rigorously respect the indications supplied by the 
manufacturer and the safety standards and regulations in force.

INSTALLATION (fig. 1-4)

Caution!

 If you install more than one FTR893C3, in order to guarantee the correct operation, 

the emission cones of the individual sensors should not overlap. 
The two beams must be separated by at least 

1,5 meters

.

1)  The sensors come complete with cables and though it is 

not possible to extend them

 you 

may shorten them (in this case it's preferable to shorten the receiver cable so as to allow it to 
be nearer the control box).

 Warning:

 Do not peel the cables back by more than 

2cm

 when wiring up to the control box as 

this will reduce the device's level of resistance to external interference.

2)  Make sure that the surfaces to which the sensor supports (

fig. 3a

) are to be fitted are not inclined 

and that they are perfectly aligned as once installed the sensors cannot be adjusted externally.

3)  Work out the point at which the control box is to be fitted by taking into account the length of the cables. 

If the control box is to be installed outdoors it must be protected by a waterproof container (

IP55

).

4)  Run the cables from the control box to the sensors (

fig. 3b

) making sure that they are not passed 

through ducts containing high tension wires. 

5)  Work out the height ("

H

fig. 2

) and mark the points at which the plastic supports are to be fitted. 

6)  Drill a Ø12 hole at each installation point (

fig. 3

).

7)  Insert the plastic supports (

fig. 3a

)

8)  Fix the sensors to the supports by first inserting the cable and then pressing down on the sensor 

until it snaps into position (

fig. 3b

). Once they have been fastened down the sensors cannot be 

extracted externally (these are anti-tampering devices).

9)  If you have replace the sensor; first disconnect the cable from the socket and then press from 

the inside towards the outside to free the sensor from its plastic support.

10) Carry out the electrical connection exactly following the attached wiring diagram (

fig. 4

). The 

minimum cable cross section area for the power cable is 

0,2 mm

2

 (

AWG #24

).

11) Select the type of output contact: 

NC/8.2 kΩ

12) Select the range as indicated in the

 table on page 4 

remembering that the range values are 

strictly dependent on a well executed installation which respects all the points specified in 

the 

paragraph "Installation".

Operational anomalies

•  The green led is off
  - Check the electrical connection
  - Check the power supply rating and polarity (

12/24 Vac/dc

).

•  The red led remains constantly lit
  - Make sure that the sensors are correctly aligned
  - make sure that the beam is not interrupted;
  - check the integrity of the sensors; 
  - check the integrity of the cables.

ITALIANO

ENGLISH

ZVL315.02: Mod.: 27-06-2011

This product has been tried and tested in the manufacturer's laboratory, du-
ring the installation of the product follow the supplied indications carefully.

MODEL

DATE

SERIAL NUMBER

SERIES

Содержание Mini FTR893 Series

Страница 1: ... verificare il collegamento elettrico verificare il valore e polarità della tensione di alimentazione 12 24 Vac dc Il led rosso rimane sempre acceso verificare che le ottiche siano correttamente allineate verificare che il raggio non sia ostacolato verificare l integrità delle ottiche verificare l integrità dei cavi MODULATED INFRARED BARRIER MINI FTR893C3 These instructions are aimed at professio...

Страница 2: ...S DEUTSCH BARRIERE A INFRAROUGE MODULE MINI FTR893C3 Remarque Ce livret est destiné à des personnes titulaires d un certificat d aptitude professionnelle pour l installation des APPAREILS ÉLECTRIQUES et requiert une bonne connaissance de la tech nique appliquée professionnellement Avant de procéder à l installation lire attentivement ce livret En particulier se familiariser avec les dispositifs de...

Страница 3: ...las superficies donde se deben fijar los soportes de plástico fig 3a están llanas y perfectamente enfrentadas entre sí ya que los dispositivos ópticos no permiten la regulación exterior 3 Determinar el punto preciso donde se va a colocar la lógica de control teniendo en cuenta la longitud de los dispositivos ópticos disponibles si la instalación se realiza al exterior del edificio la lógica de con...

Страница 4: ...sione max di contatto 30 Vac dc Corrente max 500 mA Technical specifications Power supply voltage 12 24 Vac dc Max power consumption 55 mA Operating temperature range 10 55 C Emission wavelength I R 950 nm Carrier frequency 31 kHz Modulation frequency 200 Hz Emission cone opening 7 Protection grade optical sensors IP55 Relay intervention time 25 ms Drop out delay 100 ms Max commutable power at the...