Page 12
E
XTERNAL CONNECTIONS
M
motor
T1
transformer
V1
RPM sensor
S22 reference point switch
T
photocell transmitter
R
photocell receiver
S3
push button
IMPULSE
S4
push button
STOP
X1
plug 1~N 220-240V 50Hz
H4
light bulb (max 40 Watt)
H5
signal light
0V
Ground
24V Output 24 VDC, max. 50 Ma.
RC
Relays contact
bk
black
bn
brown
or
orange
rd
red
a
brown
b
green/yellow
c
green
Wall control (push button impulse):
It is possible to either connect a push button or a 3-function wall console with impulse, light
on/off and an electronic vacation lock functions. When operator LED 4 burns and LED 3 flashes
the 'vacation' lock is activated.
De-activate 'vacation' lock on 3-function wall console or by briefly pressing
%
button on operator.