B-3 OPERATION B-3
CONTROLS AND SETTINGS
All operator controls and adjustments are located on the case front of the TIG machine. Refer to Figure B.1
and the corresponding explanations.
FIGURE B.1 CONTROL PANEL
1. FRONT PANEL 2. BACK PANEL
1.Memory chanel LED 2. Data
Display meter 3. Parameter
Select function 4.indicating light of
power 5. S -- unit of up &
downslope time & pre& post flow
time % -- unit of AC balance
&peak time on Hz-- unit of
pulse freq.&AC freq.
6. indicating light of Parameter
Select function
(
Pre-flow /Start
current/Up slope/Welding Amps
(
Pulse peak amps
)
/peak time
on/ pulse freq./base Amps/down
slope/end current/post flow/AC
freq./ AC balance/)
8.warning indicating light
9. MMA slector DC-/DC+
10.TIG PULSE slector
11.TIG slector
DC TIG/AC TIG
12. 2 T/ 4 T slector
13. Data Display Adjustment
Knob 15. output"+"
(
Welding
holder
)
16. output"-"
(
Ground clamp
)
17.argon out 18.argon arc
control (or remote control)
19.Amp Adjustment slector
(remote control)
panel/ pedal /finger torch
20. power switch
21.argon inlet 22.power
supply 23.safety earthing
column 24.fan
25.HF/Lift TIG slector
26.No use
CONTROL FUNCTIONALITY
1.
Memory Function
The unit has 9 programs which allow the operator to
select parameters then save the settings to the selected
program channel. To operate, use the selector button to
select the desired program number where the program is
to be stored. The red select light will be lit, indicating
that the welder is in the programming mode. Enter the
desired program parame-ters. After all parameter
changes have been made, press the selector button and
hold for 3 seconds and release. The green save button
will light, indicating the function has been saved. After
approximately 2 seconds, the save light will go out, and
the unit will default back to the red select light. Any
additional adjustments made after this will need to be
resaved.