1700-1800° Tube
F
USES
& P
OWER
C
ONTROL
8.1 Fuses
F1 & F2 - see the example circuit diagram.
F1
Supply
Fuses:
Supply fuses are not fitted internally unless the furnace is also fitted with a supply cable; when
fitted they are of GEC Safeclip of the type shown.
Customers should fuse at the rating shown.
F2
Control Fuses: 2 Amp type F 30mm x 6mm
Thyristor Fuse:
Ferraz Protistor of the rating shown. Note that, unlike most fuses, protistor fuses
are correctly rated at a higher current than the thyristor they are protecting.
8.2 Power Control
The setting for the power limit parameter in the controller (
OP.Hi
) should be 100% for all models.
The thyristor stacks are set to the secondary (element) maximum currents given in the table.
Model Phases volts
supply
fuse
rating type
thyristor
fuse
rating
Current
limit
(element
circuit)
CTF 17/--/300 1-phase
220-240
30-32A NS32
50A
90A
CTF 17/--/600 1-phase
220-240
50A
ES50
63A
90A
CTF 17/--/600 3-phase
380/220-415/240 25A
NS25
2 x 30A
+ 1 x 20A
134A
CTF 17/--/600 3-phase delta
220-240
25A
NS25
2 x 30A
+ 1 x 20A
134A
TZF 17/--/600 1-phase
220-240
50A
ES50
2 x 20A
+ 1 x 50A
90A
TZF 17/--/600 3-phase
380/220-415/240 30-32A NS32
2 x 20A
+ 1 x 50A
90A
TZF 17/--/600 3-phase delta
220-240
40A
ES40
2 x 20A
+ 1 x 50A
90A
CTF 18/--/300 1-phase
220-240
30-32A NS32
50A
134A
CTF 18/--/600 1-phase
220-240
50A
ES50
63A
134A
CTF 18/--/600 3-phase
380/220-415/240 25A
NS25
2 x 30A
+ 1 x 20A
134A
CTF 18/--/600 3-phase delta
220-240
40A
ES40
2 x 30A
+ 1 x 20A
134A
TZF 18/--/600 1-phase
220-240
63A
ES63
2 x 20A
+ 1 x 50A
90A
TZF 18/--/600 3-phase
380/220-415/240 32A
NS32
2 x 20A
+ 1 x 50A
90A
TZF 18/--/600 3-phase delta
220-240
63A
ES63
2 x 20A
+ 1 x 50A
90A
16