 Controller Fault 
 

22 

 

 

MC19-1.22 

8  Controller Fault 

8.1 

Fault Code Diagnostic Table 

 

Error Code  Explanation 

Actions 

S.br 

Temperature sensor failure 

Replace the Furnace or Oven 
Temperature Sensor 

 

9  Glossary of Terms 

Home display 

The first display of the controller screen, to which it returns when no 
keys are pressed. 

PID 

Proportional, Integral, Derivative: the control system used by the 
controller. 

Parameter 

A temperature or time value, or program action. 

Segment 

A program section in which a group of  parameters are set. 

Program 

A pre-set sequence of segments to control temperature changes 
and time periods. 

Measured 
temperature 

The actual temperature of the furnace or oven. 

Setpoint 
temperature (SP) 

The target temperature when operating as a controller. 

Program setpoint 
temperature (PSP) 

The target temperature as a program proceeds. 

Reset 

A single action by the operator to stop a program running and return 
to simple controller mode. 

Holdback 

Holdback can be used to prevent the PSP from running ahead of the 
actual heating or cooling. 

Ramp 

The Program Setpoint temperature rises or falls over a period of 
time. 

Rate  

The rate; in degrees per second, min or hour, of the Program 
Setpoint temperature rise or fall. 

Time  

A set time period for the Program Setpoint temperature to rise or fall. 

Step 

An immediate rise or fall in the Program Setpoint temperature. 

Dwell 

Time period during which the PSP is fixed. 

Wait 

The program waits until a selected external parameter has been 
met. 

Call 

Interrupts a program to run another program, then returns to 
continue 

End 

A segment type to end a program by either: Going into Reset and 
controlling to the SP; Dwelling at the last PSP value until Reset is 
pressed; SafeOp 

SafeOp 

Turns the power off. 

Element 

The heating device used in the furnace or oven. 

Thermocouple 

The temperature sensing device used in the furnace or oven. 

Furnace or Oven 

This refers to the product purchased from Carbolite Gero. 

Содержание 3508 P1

Страница 1: ...1 MC19 1 22 Operating Instructions Temperature Controller Type 3508 English Ack 3508 1200 EUROTHERM 23 RUN HOLD RUN HLD OP1 C 96 0 A MAN ...

Страница 2: ...3508 Controller 2 MC19 1 22 Note For the purposes of this manual the Eurotherm 3504 range is functionally identical to the 3508 range ...

Страница 3: ...Program Cycling 10 5 5 Creating a Program 11 5 6 Running a Program 12 5 7 To pause hold a program 12 5 8 To stop and reset a program 12 5 9 To run a different program P10 and P25 12 5 10 Program Status 13 5 11 Power Failure Recovery 13 5 12 Alarms 14 5 13 Program Example 1 14 5 14 Program Example 2 16 6 Options 17 6 1 Digital Communications RS232 17 6 2 Digital Communications RS485 17 6 3 Comms Ad...

Страница 4: ...re control when properly set This controller can store 10 programs of up to 50 segments each Programs can be run individually or linked by a Call parameter as sub programs or to form single long programs The 3508P10 can also be used as a simple temperature controller 3508P25 Controller Programmer The 3508 P25 is a digital temperature controller which uses PID algorithms to give excellent temperatu...

Страница 5: ...e an alarm Page and up arrow together Press together quickly to scroll back up the page headings Scroll and up arrow together Press together quickly to scroll back up a parameter list Pressing any other combination of keys together has no effect Note If no keys are pressed for 1 minute the display returns to Home Power output indicator Measurement units Measured temperature Program Setpoint temper...

Страница 6: ...wells and steps as the program runs The SP temperature of the controller does not apply when a program is running To pause the program press RUN HOLD To stop the program and return to simple controlling reset press RUN HOLD for 2 seconds When the program ends the programmer will either Automatically reset to operation as a simple controller Dwell at the last temperature of the program with the RUN...

Страница 7: ...urn to home the controller is now in level 2 When Level 2 operations have been completed the supervisor must return to Level 1 manually It is not necessary to enter a code when going from a higher level to a lower level To Return to Level 1 1 Press and hold page for 3 seconds The display will show Access Goto Level 2 2 Press down to go to level 1 After a short pause the display will revert to home...

Страница 8: ...cessible to allow compensation for element ageing Refer to the product manual for details In many models the maximum power output setting depends on the supply voltage refer to the product manual for details 4 2 Customer ID A furnace or oven identity number can be entered if required This may be used to identify one of many units for production or quality control systems Press page until Customer ...

Страница 9: ... zero power to the elements will be 0 To do this set the Setpoint temperature to the minimum possible For type B thermocouples this will be bellow zero 3 With the End segment set to Reset The controller will try to reach and maintain the Setpoint temperature 4 With the End segment set to Dwell The controller will dwell at the PSP of the last segment RUN indicator flashes until it is reset To reduc...

Страница 10: ... Wait until Inputs 1 AND 2 are true 4 PrgIn 1or2 Wait until Inputs 1 OR 2 is true 5 PVWaitIP Wait until the measured temperature reaches a threshold value before continuing It can operate in one of 4 ways 5 1 Abs Hi Wait until the measured temperature is greater than or equal to a value WaitVal set for that segment 5 2 Abs Lo Wait until the measured temperature is less than or equal to a value Wai...

Страница 11: ...ent have been entered the display goes to the next segment number Segment Type Press scroll until the display shows Segment Type Press up or down to select Rate Time Dwell Step Wait GoBack Call or End Holdback Type Press scroll until the display shows Holdback Type If required press up or down to select Off Low High or Band Target Setpoint Visible only for Rate Time and Step segments Press scroll ...

Страница 12: ... then scroll once twice for P10 and P25 then press up or down 5 7 To pause hold a program Press RUN HOLD or Press page until Program Status Reset appears Press scroll until the cursor moves to Reset Press up or down to select Hold RUN HLD will be displayed 5 8 To stop and reset a program Press and hold RUN HOLD or Press page until Program Status Reset appears Press scroll until the cursor moves to...

Страница 13: ...see Programming and the program goes into a hold state the green HLD indicator will flash until the measured temperature catches up If while in this condition the program itself is put into hold by pressing the RUN HLD button the HLD indicator will stop flashing and remain on with the RUN indicator When the program is started again by pressing the RUN HLD button the HLD indicator will flash again ...

Страница 14: ...ndicate the type of alarm To acknowledge an alarm and cancel the ALM indicator press and together 5 13 Program Example 1 The following sequence of entries creates and runs the program shown graphically below 1 Turn the controller SP down to 0 by pressing down 2 Press page until Prog Segments Used is displayed On P10 or P25 models press up or down to select a new program number a program with only ...

Страница 15: ...press RUN HOLD or 14 Press page until Program Status is displayed 15 Press scroll until the cursor moves to the program status of Reset 16 Press to select Run Segment 1 Type Rate Target 400 Rate 5 0 Min Segment 2 Type Dwell Duration 30min Segment 3 Type Step Target 600 Segment 4 Type Dwell Duration 30min Segment 5 Type Time Target 200 Time 2 hours Segment 6 Type End End type Reset 400 C 600 C 200 ...

Страница 16: ...es Note Call segments are not available on single program models Segment Type Rate Target SP 400 degrees Ramp Rate 2 0 degrees per minute Segment Type Step Target SP 200 degrees Segment Type Dwell Holdback High Duration 30 00 0 minutes Segment Type Call Call Prog next number Call Cycles 2 Finish the program with an End segment 11 Press scroll until Segment Type is displayed Press up or down to sel...

Страница 17: ... end and 9 pin at the computer but other alternatives are shown in parentheses Furnace end of cable RS232 Cable furnace to PC Computer end of cable female 9 pin 25 pin 9 pin 25 pin male Rx 3 2 3 2 Tx Tx 2 3 2 3 Rx Com 5 7 5 7 Com 7 8 4 5 Link together 1 4 6 6 8 20 Link together 6 2 Digital Communications RS485 If an RS485 option is supplied then the furnace is fitted with two D sockets Connection ...

Страница 18: ...ied may be switched on and off using the Remote setpoint enable parameter in the controller level 2 if this was made available for a particular application In level 2 press page until REM SP Enable is displayed press up or down to select SP1 the normal controller setpoint or SP2 the remote input setpoint SPX will appear in the top left corner of the display Remote output does not require switching...

Страница 19: ...Setpoint Ramp units Prog cycles Prog segment Segment type Rate Time Dwell Step Call End Segment target Segment target Duration Segment target Call Program End Type Ramp rate Duration Call Cycles Visible parameters depend on Segment Type Customer Identity Controller Identity when using more than one Read only Program number Wait Wait For options GoBack Segment GoBack GoBack Cycles Holdback Type Hol...

Страница 20: ...ram nr See previous diagram Read only Segment nr type Change program status Program Setpoint Current Segment Type Rate Time Dwell Wait Segment Target Segment Target Segment Rate Segment Rate Cycles Left Program Time Left Controller identity when using more than one Segment time remaining program status Visible parameters depend on Segment Type ...

Страница 21: ...t Program nr P See previous diagram S S See level 1 diagrams See level 1 diagrams Controller identity when Do not raise the power limit if accessible above the design level for the Home display Press hold for 3 seconds Access Goto Level 1 Press to select Level 2 Access Pass code Press to select code 9 Home display Level 1 Level 2 To enter Level 2 Level 2 ...

Страница 22: ...rator to stop a program running and return to simple controller mode Holdback Holdback can be used to prevent the PSP from running ahead of the actual heating or cooling Ramp The Program Setpoint temperature rises or falls over a period of time Rate The rate in degrees per second min or hour of the Program Setpoint temperature rise or fall Time A set time period for the Program Setpoint temperatur...

Страница 23: ...Navigation 23 MC19 1 20 ...

Страница 24: ...ngland Telephone 44 0 1433 620011 Fax 44 0 1433 621198 E mail info carbolite gero com For preventive maintenance repair and calibration of all Furnace and Oven products please contact Carbolite Gero Service Telephone 44 0 1433 624242 Fax 44 0 1433 624243 Email ServiceUK carbolite gero com MC19 1 22 01 01 16 ...

Отзывы: