9.2 Power Settings
The power limit settings (OP.Hi) for this model is as follows. The figures represent the
maximum percentage of time that controlled power is supplied to the elements. Do not
attempt to "improve performance" by setting a value higher than the one from the
table. To adjust the parameter refer to the "Changing the Maximum Output Power" of
the control section of the manual.
All standard models covered by this manual are fitted with elements designed for use
over the range of voltages 200 V-240 V; the power limit parameter is set according to
the table below. These models may be relocated to a different voltage within the range
The power limit depends on the voltages follows:
Voltage
100 V
120 V
200 V
208 V
220 V
230 V
240 V
Percentage (%)
100
77
100
100
92
84
75
Non-standard Models
Non-standard voltages may not follow the table above. Check the default setting please
refer to controller instructions.
Please refer to the rating label for product specific information.